InterVac H Installation And Operating Manual

The compact central vacuum specialist

Advertisement

Quick Links

THE COMPACT CENTRAL VACUUM SPECIALIST
INSTALLATION and OPERATING MANUAL
120 VOLT
Model H
IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCES A PROBLEM WITH YOUR INTERVAC
PRODUCT, DO NOT RETURN THIS PRODUCT TO THE STORE OR DEALER
PLEASE CALL US DIRECT 1-888-499-1925, we are here to help.
This manual must be read and understood before installation, adjustment, service, or maintenance is
performed. This unit should be installed by a qualified technician. Modification of this product can be extremely
hazardous and could result in personal injury or property damage. Instructions must stay with unit.
Phone 772-463-1400 • USA & Canada toll free 888-499-1925
www.intervacdesign.com • e-mail: sales@intervacdesign.com
Model: H
surface mounted with power cord attached
Model: RMH
Models RMH
WARNING: Owner read carefully.
InterVac Design
Corp., Palm City, FL 34990
2939 SW 42nd Avenue
surface mounted with power cord attached
RECORD THIS INFORMATION
FOR FUTURE REFERENCES
MODEL NUMBER ____________________
DATE OF PURCHASE ________________
PLACE OF PURCHASE _______________
Manual #
M-11
Rev.: 3/31/2022
Model RMD, special order

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H and is the answer not in the manual?

Questions and answers

Summary of Contents for InterVac H

  • Page 1 Models RMH Model RMD, special order IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCES A PROBLEM WITH YOUR INTERVAC PRODUCT, DO NOT RETURN THIS PRODUCT TO THE STORE OR DEALER PLEASE CALL US DIRECT 1-888-499-1925, we are here to help.
  • Page 2: Important Safety Instructions

    LIMITED WARRANTY InterVac Design Corp. will repair the power unit with new or rebuilt parts, free of charge for two (2) years in North America from the date of original purchase in the event of a defect in materials or workmanship. Warranty might vary from country to country.
  • Page 3: Installations

    RAZOR BLADES, NEEDLES, PINS OR OTHER SHARP OBJECTS! INSTALLATIONS MODEL: H-Surface Mounted with power cord attached, External to Wood or Dry-wall Surfaces: (see Fig.: A) Step 1. To cover with the vacuum hose as much area as possible, choose a wall or surface that is centrally located and has an electrical outlet close by.
  • Page 4: Wiring Instructions

    Please, check that dust bag and motor filter (under dust bag) are installed. Motor filter should lay flat on all 4 corners under the ribs! IMPORTANT: If installed during new construction, do not use to clean up building debris. For household use only. Nails and sharp objects can damage your InterVac. WIRING INSTRUCTIONS: Please Note: Models...
  • Page 5 Model RMF In-Wall Mounted, hard wired connection, Romex Recessed Mounted into Wood Surface ( see Fig.: B NOTE: Installation should be accessible from the back to install pipe fittings and wiring connection. Step 1. Attach paper template to wall or surface about 2” inches or higher above the floor, so that the exhausting air, coming out of bottom of the vacuum, is not restricted.
  • Page 6: Fitting Assembly

    Counterclockwise, screw threaded coupling into flex-hose. Press-fit the other side into the fittings with a strong twist. No need to glue. interVac Design Palm City, FL. 3-2016 Intake fitting is supplied in the power units vacuum chamber rev.: 9-2017 AF-10-E, AF-10-W...
  • Page 7 No need to glue. Intake fitting is supplied in the power units vacuum chamber if you use the elbow, INTERVAC DESIGN CORP. P21, one side has to be PALM CITY. FL glued to the VacPort. DATE: 6-2014...
  • Page 8 HOW TO OPERATE MODEL: H NOTE: THE LOWER PART OF THE VACUUM CLEANER WILL BE QUITE WARM WHEN IN USE. IF THE VACUUM STOPS RUNNING: Most likely the vacuum hose is clogged, and the motor shuts off. Push the switch into OFF position and let the motor cool down.
  • Page 9: How To Operate Your

    HOW TO OPERATE YOUR MODEL RMH NOTE: THE LOWER PART OF THE VACUUM CLEANER CAN BE QUITE WARM. IF THE VACUUM STOPS RUNNING: Disconnect the vacuum hose from the unit and let the vacuum cool. The thermal protector on the motor will reset itself after the motor is cooled. The most likely cause will be a full bag or clogged vacuum hose or tools.
  • Page 10 MODEL RMD with Electric Cord or Permanent Installation Please note: the installation for the model RMD is the same as for the models RM You can insert the vacuum hose in the door on the front panel as well as in the remote mounted vacuum valve.
  • Page 11 Fig.: E D: Replacing Exhaust Filter, E. Replacing motor filter, Part #Y41: IF SUPPLIED, all Models, Part # Y21 Pinch exhaust filter in the middle and pull out. tuck-in the corners and sides To replace, pinch in the middle and slide in carefully under the ribs one side first.
  • Page 12 "VacPort.com" for RM Models Air Turbo Nozzle Elongated Dust Brush PART# AS-21 for all RM Models PART# X451 Model A910 w/o LED light PART# X251 Model A900 with LED light INTERVAC reserves the right to make improvements and modifications without notice.
  • Page 13 Most effective installation. The receiver box with electric Minimal wall cord mounts next to the central vacuum power unit. other InterVac Models Model RM-H Model H Installed as a traditional (GF120 without central vacuum system the tool caddy)
  • Page 14 #L-40 (W600) Template # L-40 (W600) TEMPLATE for SCREW CENTERS Modele papier for surface mounting vacuum mark all 4 centers accurately marquer tous les 4 centres pattern of keyholes from avec précision. the back of the vacuum. modele de serrure a l'arriere de l'aspirateur Installing Vacuum to a wall stud Use 2 screws without plastic anchors for the wall stud.

This manual is also suitable for:

Rmh

Table of Contents