QuadVoltV2-160mV
4-Channel ±160 mV Low Level DC
Voltage Data Logger
QuadVoltV2-3.2V
4- C hannel ± 3.2 V Low Level DC
Voltage Data Logger
QuadVolt-32V
4- C hannel -8 V to 32 V Low Level
DC Voltage Data Logger
QuadVoltV2 and OctVoltV2
OctVolt-160mV
8-Channel ± 160 mV Low Level DC
Voltage Data Logger
OctVolt-3.2V
8- C hannel ± 3.2 V Low Level DC
Voltage Data Logger
OctVolt-32V
8- C hannel -8 V to 32 V Low Level
DC Voltage Data Logger
To view the full MadgeTech product line,
visit our website at madgetech.com.

Advertisement

loading

Summary of Contents for MadgeTech QuadVoltV2

  • Page 1 4- C hannel -8 V to 32 V Low Level 8- C hannel -8 V to 32 V Low Level DC Voltage Data Logger DC Voltage Data Logger To view the full MadgeTech product line, visit our website at madgetech.com.
  • Page 2: Table Of Contents

    QuadVoltV2 and OctVoltV2 Quick Start Steps ........... 1 Additional Features & Operation ....2-3 Product Maintenance ........3 Recalibration ..........3 General Specifications ........4 Support ........Back Cover To view the full MadgeTech product line, visit our website at madgetech.com.
  • Page 3: Quadvoltv2 And Octvoltv2

    Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Wizard. Install the MadgeTech 4 Software and USB Drivers onto a Windows PC.
  • Page 4: Additional Features & Operation

    Product User Guide Additional Features and Operation Wiring the Data Logger QuadVoltV2 and OctVoltV2 Single Ended Wiring (3.2 V and 32 V) Two-position removable screw terminal connections; accepts 2-wire configurations. Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
  • Page 5: Product Maintenance

    Prices and specifications subject to change. See MadgeTech’s terms and conditions at To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting madgetech.com, then under the services tab, select RMA Process.
  • Page 6: General Specifications

    (69 mm x 184 mm x 26 mm) (69 mm x 184 mm x 32 mm) Weight 17 oz (490 g) 15 oz (420 g) *QuadVoltV2 & OctVoltV2 Range, Resolution and Calibrated Accuracy Nominal Range ± ± 160 mV 3.2 V...
  • Page 7 If possible, try switching the battery with a new 9V lithium. • Ensure that no other MadgeTech software (such as MadgeTech 2) is running in the background. • Ensure that the Connected Devices panel is large enough to display devices. This can be verified by positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then dragging the edge of the panel to resize it.