Summary of Contents for ICP DAS USA TP-4100

  • Page 1 TPM-4100/TP-4100/TP-2070/ TP-3080/TP-5120/TP-6150/ TP-7170 Touch Panel Monitor User Manual Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 1 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 2  Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, beginning from the date of delivery to the original purchaser.  Warning ICP DAS assumes no liability for any damage resulting from the use of this product. ICP DAS reserves the right to change this manual at any time without notice.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents ..........3 1. Introduction ..........6 1.1. Features ..............8 1.2. Specifications ............. 9 1.3. Dimension ..............15 1.4. I/O interfaces ............29 1.5. Companion CD ............31 1.6. System Setup ............32 1.6.1. System Configuration ......... 32 1.6.2.
  • Page 4 2.2.1.3. Uninstalling the XP-8000-CE6 ..61 2.2.1.4. Other Windows CE6.0 Devices ... 63 2.2.2. Serial Touch Driver ........64 2.2.2.1. Installation for XP-8000-CE6 ..65 2.2.2.2. Configuration for XP-8000-CE6 ... 68 2.2.2.3. Uninstalling the XP-8000-CE6 ..70 2.2.2.4. Other Windows CE 6.0 Device ..72 2.3.
  • Page 5 Appendix A. Tips .......... 115 A.1. Don’t install USB and serial touch driver simultaneously in a device 115 A.2. Don’t plug USB cable when using serial touch driver116 Appendix B. Revision History ..... 117 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 5 Copyright ©...
  • Page 6: Introduction

    1. Introduction This chapter provides an overview of the TPM-4100/TP-4100/TP-2070/TP-3080/T P-5120/TP-6150/TP-7170 and its components. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 6 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 7 Panel Mount Monitor includes a standard TFT LCD screen with a rugged aluminum front bezel resolution and a wide operating temperature range. The TPM-4100/TP-4100/TP-2070/TP-3080/TP-5120/TP-6150/TP-7170 is also guaranteed to integrate with ICP DAS PAC control systems, such as WP-8000 series, LinPAC-8000 series and the XP-8000 series.
  • Page 8: Features

    1.1. Features  Support resolution Mode name Size Resolution TP-2070 7” 800 x 480 TP-3080 8.4” TPM-4100/TP-4100 10.4” 800 x 600 TP-5120 12.1” TP-6150 15” 1024 x 768 TP-7170 17” 1280 x1024  Full-function OSD control keys for optimizing the display ...
  • Page 9: Specifications

    1.2. Specifications The table below is a summary of the specifications of the touch panel, and lists the accessories that are supported by the touch panel. Specifications Model TP-2070 Display Size 7” Resolution 800 x 480 Luminance 400 cd/m2 Touch screen 4-wire, analog resistive;...
  • Page 10 Model TP-3080 Display Size 8.4” Resolution 800 x 600 Max. Color 16.7 M Luminance 400 cd/m2 Touch screen 5-wire, analog resistive; Light Transmission: 80% Contrast ratio 500:1 Viewing angle (H/V) 140/130 Backlight life (hrs) 50,000 Touchscreen function Combo RS-232 & USB interface Input signal VGA (analog RGB) MMI (Man Machine Interface)
  • Page 11 Model TPM-4100 TP-4100 Display Size 10.4” Resolution 800 x 600 Max. colors 16.7 M Luminance 400 cd/m2 5-wire, analog resistive 5-wire, analog resistive Touch screen Light Transmission: 80% Light Transmission: 80% Contrast ratio 500:1 Viewing angle (H/V) 140/130 Backlight life (hrs)
  • Page 12 Model TP-5120 Display Size 12.1” Resolution 800 x 600 Max. Color 16.7 M Luminance 400 cd/m2 Touch screen 5-wire, analog resistive; Light Transmission: 80% Contrast ratio 500:1 Viewing angle (H/V) 140/130 Backlight life (hrs) 50,000 Touchscreen function Combo RS-232 & USB interface Input signal VGA (analog RGB) MMI (Man Machine Interface)
  • Page 13 Model TP-6150 Display Size 15” Resolution 1024 x 768 Max. colors 16.7 M Luminance 400 cd/m2 Touch screen 5-wire, analog resistive Light Transmission: 80% Contrast ratio 500:1 Viewing angle (H/V) 140/130 Backlight life (hrs) 50,000 Touchscreen function Combo RS-232 & USB interface Input signal VGA (analog RGB) MMI (Man Machine Interface)
  • Page 14 Model TP-7170 Display Size 17” Resolution 1280 x 1024 Max. colors 16.7 M Luminance 350 cd/m2 Touch screen 5-wire, analog resistive Light Transmission: 80% Contrast ratio 500:1 Viewing angle (H/V) 140/130 Backlight life (hrs) 50,000 Touchscreen function Combo RS-232 & USB interface Input signal VGA (analog RGB) MMI (Man Machine Interface)
  • Page 15: Dimension

    1.3. Dimension TP-2070 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 15 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 16 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 16 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 17 TP-3080 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 17 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 18 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 18 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 19 TP-5120 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 19 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 20 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 20 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 21 TPM-4100 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 21 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 22 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 22 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 23 TP-4100 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 23 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 24 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 24 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 25 TP-6150 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 25 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 26 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 26 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 27 TP-7170 (Unit: mm) Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 27 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 28 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 28 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 29: I/O Interfaces

    1.4. I/O interfaces TP-2070 TP-3080/TP-5120/TP-6150/TP-7170 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 29 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 30 TPM-4100 TP-4100 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 30 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 31: Companion Cd

    1.5. Companion CD This package includes a companion CD that contains a collection of documentation and device drivers. An outline of the folder structure is illustrated below. Win_XP_7 Touch Driver for Windows 2K/XP/2003/2008/Vista/7 CD:\[Model] Win_XP_Embedded XP-8000 device Touch Driver for the XP-8000 series WinCE V5.0 WP-8000 and WP-5000 device...
  • Page 32: System Setup

    This section gives details regarding system configuration and adjustment and mounting options. 1.6.1. System Configuration There are two kinds of OSD menu in the following description. TP-2070/TP-4100/TPM-4100 support the following OSD menu. Control Function Adjust V-Position, H-Position, Clock and Clock and Clock-Phase...
  • Page 33 H-position Move the screen left or right V-position Moves the screen up or down Color temperature Color setting NATIVE Color temperature 9300K Color temperature 6500K USER Making adjustments to the R/G/B content. Support 8 languages. OSD setting Language Move the OSD position horizontally on the screen.
  • Page 34 Shift the icon to the left side or shift it down. Shift the icon to the right side or shift it up. 1. Enter the OSD menu. 2. Enter the adjustment item. Executing auto adjustment. RUN (Data) and PWR (Power) LED The RUN (Data) LED and PWR(Power) LED are situated in the top right-hand corner.
  • Page 35 1024 x 768 Don’t care 800 x 600 Don’t care XP-8x4x-CE6 1290 x 1024 TP-2070: not support TP-4100/TPM-4100: 60/70/75 1152 x 864 TP-2070: 70/75 TP-4100/TPM-4100: 60/70/75 1024 x 768 60/70/75 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 35 Copyright ©...
  • Page 36 800 x 600 60/70/75 640 x 480 60/70/75 The following display modes are supported for other devices. Resolution Horiz. Sync. Vert. Sync. 640 x 480 31.4 KHz 50 Hz 31.4 KHz 59.9 Hz 37.5 KHz 75 Hz 720 x 400 31.4 KHz 70 Hz 800 x 600...
  • Page 37: Panel Mounting

    1.6.2. Panel Mounting Insert the mounting brackets. Screw the mounting bracket to the unit. Eight locations are available for attaching four mounting clamps to secure the unit. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 37 Copyright ©...
  • Page 38 Panel thickness up to 6 mm. Refer to Sec.1.3 for default information regarding the dimensions of the panel. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 38 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 39: Touch Driver Setup

    2. Touch Driver Setup This chapter provides a overview that describes the steps required for installing, uninstalling, and configuring the touch driver. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 39 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 40: Windows Ce 5.0

    2.1. Windows CE 5.0 This section describes how to install, calibrate and uninstall the touch driver for the WP-8000 series and WP-5000 series, and gives details of how to obtain drivers for other CE5 devices. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 40 Copyright ©...
  • Page 41: Usb Touch Driver

    2.1.1. USB Touch Driver Two USB touch drivers are available. The first is for WP-8000 series modules and WP-5000 series modules of ICP DAS PAC controllers, and the second is for other Windows CE5.0 systems. WP-8000 series: WP-8131/WP-8431/WP-8831, WP-8141/WP-8441/WP-8841 WP-8137/WP-8437/WP-8837, WP-8147/WP-8447/WP-8847 WP-8139/WP-8431/WP-8839, WP-8141/WP-8441/WP-8849 WP-8136/WP-8431/WP-8836, WP-8141/WP-8441/WP-8846 WP-5000 series:...
  • Page 42: Installation For Winpac-8000 And Winpac-5000

    2.1.1.1. Installation for WinPAC-8000 and WinPAC-5000 The following procedure describes how to install the PenMount USB touch driver. Copy the driver from the CD-ROM to the WinPAC. The “PenMount_USB_TOUCH_Vyyyymmdd.CAB” driver file can be obtained from: [name] Driver path TP-2070/TP-3080/TP-5120 CD:\[name]\Driver\WinCE\V5.0\WP-8000 and WP-5000 device TPM-4100_TP-4100/ For example: TP-6150/TP-7170...
  • Page 43 Tips 1. Appendix A  “A.1. Don’t install USB and serial touch driver simultaneously in a device” Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 43 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 44: Configuration For Winpac-8000 And Winpac-5000

    2.1.1.2. Configuration for WinPAC-8000 and WinPAC-5000 Calibration 1. From the “Start” menu, click “Programs””USB_TOUCH” ”PenMount””Calibration”. 2. Follow the instructions on the screen to begin calibration. 3. Once calibration has been completed, from the “Start” menu, click ”Programs”Open the “WinPAC Utility”, and then click the “Save and Reboot”...
  • Page 45 Simulating the Right Mouse Button 1. From the Start menu, click “Programs””USB_TOUCH” ”PenMount””RightButton”. 2. Show a screen below (Left picture) Click the “mouse”  Turn into right picture. Become Click the “mouse” 3. Click any object: Click “My device” to test if the function of “RightButton” works.
  • Page 46: Uninstalling The Winpac-8000 And Winpac-5000

    2.1.1.3. Uninstalling the WinPAC-8000 and WinPAC-5000 The following procedure describes how to uninstall the PenMount USB touch driver. 1. From the “Start” menu, click “Programs””USB_TOUCH” ”PenMount””Uninstall”. 2. A warning pop-up will be displayed asking you to confirm the uninstall request. Click the “Yes” button to uninstall the driver. 3.
  • Page 47: Other Windows Ce5.0 Devices

    2.1.1.4. Other Windows CE5.0 Devices The driver for using with other windows CE5.0 devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 47 Copyright ©...
  • Page 48: Serial Touch Driver

    2.1.2. Serial Touch Driver Two serial touch drivers are available. The first is for WP-8000 series modules and WP-5000 series modules of ICPDAS PAC controllers, and the second is for other Windows CE5.0 systems. WP-8000 series: WP-8131/WP-8431/WP-8831, WP-8141/WP-8441/WP-8841 WP-8137/WP-8437/WP-8837, WP-8147/WP-8447/WP-8847 WP-8139/WP-8431/WP-8839, WP-8141/WP-8441/WP-8849 WP-8136/WP-8431/WP-8836, WP-8141/WP-8441/WP-8846 WP-5000 series:...
  • Page 49: Installation For Winpac-8000 And Winpac-5000

    2.1.2.1. Installation for WinPAC-8000 and WinPAC-5000 The following procedure describes how to install the PenMount serial touch driver. Note that the default COM port for serial touch driver is COM4. There is a RS-232 cable in the shipping package (Sec.1). The user can directly use this cable to connect the monitor with COM4 of WinPAC-8000 to use serial touch driver to do a touch operation by serial way.
  • Page 50 [name] Driver path TP-2070/TP-3080/TP-5120/ CD:\[name]\Driver\WinCE\V5.0\WP-8000 and WP-5000 device TPM-4100_TP-4100/TP-6150 For example: /TP-7170 CD:\TP-6150 \Driver\WinCE\V5.0\WP-8000 and WP-5000 device Or go to the “\System_Disk\External_device_driver\” folder on the WinPAC. Double-click the “ ” file. PenMount_Serial_TOUCH_Vyyyymmdd(PM6000R).CAB Show one of two dialogs below. Just click “OK” button to continue installation.
  • Page 51 Tips 1. Appendix A  “A.1. Don’t install USB and serial touch driver simultaneously in a device” 2. Appendix A  “A.2. Don’t plug USB cable when using serial touch driver” Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 51 Copyright ©...
  • Page 52: Configuration For Winpac-8000 And Winpac-5000

    2.1.2.2. Configuration for WinPAC-8000 and WinPAC-5000 Calibration 1. From the “Start” menu, click “Programs””Serial_TOUCH” ”PenMount””Calibration”. 2. Follow the instruction on the screen to begin calibration. 3. Once calibration has been completed, from the “Start” menu, click ”Programs”Open the “WinPAC Utility”, and then click the “Save and Reboot”...
  • Page 53 Changing the COM Port 1. From the “Start” menu, click “Programs””Serial_TOUCH” ”PenMount””SetCOM”. 2. In the pop-up dialog, select the COM Port you wish to use as default and click the “Set” button to save the changes. 3. From the “Start” menu, click ”Programs”Open the “WinPAC Utility”, and then click the “Save and Reboot”...
  • Page 54: Uninstalling The Winpac-8000 And Winpac-5000

    2.1.2.3. Uninstalling the WinPAC-8000 and WinPAC-5000 The following procedure describes how to uninstall the PenMount serial touch driver. 1. From the “Start” menu, click “Programs””Serial_TOUCH” ”PenMount””Uninstall” 2. A warning pop-up will be displayed asking you to confirm the uninstall request. Click the “Yes” button to uninstall the driver. 3.
  • Page 55: Other Windows Ce5.0 Devices

    2.1.2.4. Other Windows CE5.0 Devices The driver for using with other windows CE5.0 devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 55 Copyright ©...
  • Page 56: Windows Ce 6.0

    2.2. Windows CE 6.0 This section describes how to install, calibrate and uninstall the touch driver for the XP-8000-CE6 series, and gives details of how to obtain drivers for other CE6 devices. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 56 Copyright ©...
  • Page 57: Usb Touch Driver

    2.2.1. USB Touch Driver Two USB touch drivers are available. The first is for XP-8000-CE6 series modules of ICP DAS PAC controllers and, and the second is for other Windows CE6.0 systems. XP-8000-CE6 series: 1. Using the ATOM CPU: XP-8141-Atom-CE6/XP-8341-Atom-CE6/XP-8741-Atom-CE6 XP-8147-Atom-CE6/XP-8347-Atom-CE6/XP-8747-Atom-CE6 XP-8149-Atom-CE6/XP-8349-Atom-CE6/XP-8749-Atom-CE6 2.
  • Page 58: Installation For Xp-8000-Ce6

    2.2.1.1. Installation for XP-8000-CE6 The following procedure describes how to install the PenMount USB touch driver. 1. Copy the driver from the CD-ROM to the XP-8000-CE6. The “PenMount_USB_TOUCH_Vxx_yyyymmdd_XPAC_CE6.CAB” driver file can be obtained from: [name] Driver path CD:\[name]\Driver\WinCE\V6.0\XP-8000-CE6 device\ TP-2070/TP-3080/ For example: TPM-4100_TP-4100/ CD:\TP-2070\Driver\WinCE\V6.0\XP-8000-CE6 device\...
  • Page 59 Using the ATOM CPU Using the LX800 CPU 4. Once the installation has been completed, a dialog will be displayed advising that the system needs to be rebooted. Click the “OK” button to reboot the XP-8000-CE6. Tips 1. Appendix A  “A.1. Don’t install USB and serial touch driver simultaneously in a device”...
  • Page 60: Configuration For Xp-8000-Ce6

    2.2.1.2. Configuration for XP-8000-CE6 Calibration 1. From the “Start” menu, click “Programs””USB_TOUCH” ”PenMount””Calibration”. 2. Following the instructions on the screen to begin calibration. Simulating the Right Mouse Button For details of how to simulate right mouse button functions, please refer to the process described in “Simulating the Right Mouse Button”...
  • Page 61: Uninstalling The Xp-8000-Ce6

    2.2.1.3. Uninstalling the XP-8000-CE6 The following procedure describes how to uninstall the PenMount USB touch driver. 1. From the “Start” menu, click “Settings””Control Panel”. 2. Double click the “Remove Programs” icon and select “ICPDAS USB PenMount” from the “Programs” panel in the “Remove Programs” dialog box and then click the “Remove”...
  • Page 62 3. Once the uninstallation process is complete, a dialog will be displayed requesting that you reboot the system. Click the “Yes” button to reboot immediately or click the “No” button if you intend to reboot at a later time. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 62 Copyright ©...
  • Page 63: Other Windows Ce6.0 Devices

    2.2.1.4. Other Windows CE6.0 Devices The driver for using with other windows CE6.0 devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 63 Copyright ©...
  • Page 64: Serial Touch Driver

    2.2.2. Serial Touch Driver Two serial touch drivers are available. The first is for XP-8000-CE6 series modules of ICPDAS PAC controllers and the second is for other Windows CE6.0 systems. XP-8000-CE6 series: 1.Using ATOM CPU XP-8141-Atom-CE6/XP-8341-Atom-CE6/XP-8741-Atom-CE6 XP-8147-Atom-CE6/XP-8347-Atom-CE6/XP-8747-Atom-CE6 XP-8149-Atom-CE6/XP-8349-Atom-CE6/XP-8749-Atom-CE6 2.Using LX800 CPU XP-8041-CE6/XP-8341-CE6/XP-8741-CE6 XP-8047-CE6/XP-8347-CE6/XP-8747-CE6 XP-8049-CE6/XP-8349-CE6/XP-8749-CE6...
  • Page 65: Installation For Xp-8000-Ce6

    2.2.2.1. Installation for XP-8000-CE6 The following procedure describes how to install the PenMount Serial touch driver. Note that the default COM Port for the touch driver is COM5. There is a RS-232 cable in the shipping package (Sec.1). The user can directly use this cable to connect the monitor with COM5 of XP-8000-CE6 to use serial touch driver to do a touch operation by serial way.
  • Page 66 CD:\[name]\Driver\WinCE\V6.0\XP-8000-CE6 device\ TP-2070/TP-3080/ For example: TPM-4100_TP-4100/ CD:\TP-2070\Driver\WinCE\V6.0\XP-8000-CE6 device\ TP-5120/TP-6150/TP-7170 Or go to the “\System_Disk\External_device_driver” folder on the XP-8000-CE6. 2. Double click the “ ” PenMount_Serial_TOUCH_Vxx_yyyymmdd_XPAC_CE6(PM6000R).CAB file Tips & Warnings The driver (*.cab) file can only be used once. If you attempt to use it to install driver a second time, a warning dialog with a message similar to “<filename>is not a valid Windows CE Setup file”...
  • Page 67 4. Once the installation has been completed, a dialog will be displayed advising that the system needs to be rebooted. Click the “OK” button to reboot the XP-8000-CE6. Tips 1. Appendix A  “A.1. Don’t install USB and serial touch driver simultaneously in a device”...
  • Page 68: Configuration For Xp-8000-Ce6

    2.2.2.2. Configuration for XP-8000-CE6 Calibration 1. From the “Start” menu, click “Programs””Serial_TOUCH” ”PenMount””Calibration” 2. Follow the instruction on the screen to begin calibration. You will be presented with one of two screens depending on the CPU you are using. If you are using the LX800 CPU, the screen will look like this.
  • Page 69 Change the COM Port 1. From the “Start” menu, click “Programs””Serial_TOUCH” ”PenMount””SetCOM”. 2. Just choose the COM portClick “Set” buttonClick “Yes” button to reboot the system. The baudrate for the touch monitor is 19200 bps, so please don’t modify the baudrate of touch driver. Simulating Right Mouse Button For details of how to configure right mouse button simulation, please refer to the process describes in “Simulating the Right Mouse Button”...
  • Page 70: Uninstalling The Xp-8000-Ce6

    2.2.2.3. Uninstalling the XP-8000-CE6 The following procedure describes how to uninstall the PenMount serial touch driver. 1. From the “Start” menu, click “Settings””Control Panel”. 2. Double click the “Remove Programs” icon and select “ICPDAS Serial PenMount” from the “Programs” panel in the “Remove Programs” dialog box and then click the “Remove”...
  • Page 71 3. Once the uninstallation process is complete, a dialog will be displayed requesting that you reboot the system. Click the “Yes” button to reboot immediately or click the “No” button if you intend to reboot at a later. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 71 Copyright ©...
  • Page 72: Other Windows Ce 6.0 Device

    2.2.2.4. Other Windows CE 6.0 Device The driver for using with other windows CE6.0 devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 72 Copyright ©...
  • Page 73: Windows Ce 7.0

    2.3. Windows CE 7.0 This section describes how to install, calibrate and uninstall the touch driver for the WP-5000-CE7 series, and gives details of how to obtain drivers for other CE7 devices. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 73 Copyright ©...
  • Page 74: Usb Touch Driver

    2.3.1. USB Touch Driver Two USB touch drivers are available. The first is for WP-5000-CE7 series modules of ICP DAS PAC controllers and, and the second is for other Windows CE7.0 systems. WP-5000-CE7 series: WP-5231-CE7/WP-5238-CE7 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 74 Copyright ©...
  • Page 75: Installation For Winpac-5000-Ce775

    2.3.1.1. Installation for WinPAC-5000-CE7 The following procedure describes how to install the PenMount USB touch driver. 1. Copy the driver from the CD-ROM to the WinPAC. The “PenMount_USB_TOUCH_Vyyyymmdd.CAB” driver file can be obtained from: [name] Driver path TP-2070/TP-3080/TP-5120 CD:\[name]\Driver\WinCE\V7.0\WP-5000-CE7 device TPM-4100_TP-4100/ For example: TP-6150/TP-7170...
  • Page 76 b. If HIVE Registry is “Manual Save To Flash”, click “Save and Reboot” Tips 1. Appendix A  “A.1. Don’t install USB and serial touch driver simultaneously in a device” Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 76 Copyright ©...
  • Page 77: Configuration For Winpac-5000-Ce7

    2.3.1.2. Configuration for WinPAC-5000-CE7 Calibration 1. Go to “System_Disk\Drivers\USB_TOUCH\PenMount\BIN” and double click “calibrate.exe”. 2. Follow the instructions on the screen to begin calibration. 3. Once calibration has been completed, from the “Start” menu, click ”Programs”Open the “PAC Utility” a. If HIVE Registry is “Auto Save Flash(Default)”, click “reboot” b.
  • Page 78 Simulating the Right Mouse Button 1. Go to “System_Disk\Drivers\USB_TOUCH\PenMount\BIN” and double click “rbutton.exe”. 2. Show a screen below (Left picture) Click the “mouse”  Turn into right picture. Become Click the “mouse” 3. Click any object: Click “My device” to test if the function of “RightButton” works.
  • Page 79: Uninstalling The Winpac-5000-Ce779

    2.3.1.3. Uninstalling the WinPAC-5000-CE7 The following procedure describes how to uninstall the PenMount USB touch driver. 1. Go to “System_Disk\Drivers\USB_TOUCH\PenMount\BIN” and double click “Uninstall_USB_Penmount.exe”. 2. A warning pop-up will be displayed asking you to confirm the uninstall request. Click the “Yes” button to uninstall the driver. 3.
  • Page 80: Other Windows Ce7.0 Devices

    2.3.1.4. Other Windows CE7.0 Devices The driver for use with other windows CE7.0 devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en/ Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 80 Copyright ©...
  • Page 81: Serial Touch Driver

    2.3.2. Serial Touch Driver Two serial touch drivers are available. The first is for WP-5000-CE7 series modules of ICPDAS PAC controllers, and the second is for other Windows CE7.0 systems. WP-5000-CE7 series: WP-5231-CE7/WP-5238-CE7 Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 81 Copyright ©...
  • Page 82: Installation For Winpac-5000-Ce782

    2.3.2.1. Installation for WinPAC-5000-CE7 The following procedure describes how to install the PenMount serial touch driver. Note that the default COM port for serial touch driver is COM4. Please use COM1 or COM2 to communicate with the touch panel. Please note the position of TX and RX of COM port.
  • Page 83 Show one of two dialogs below. Just click “OK” button to continue installation. Click “OK” button From the “Start” menu, click ”Programs”Open the “PAC Utility”: a. If HIVE Registry is “Auto Save Flash(Default)”, click “reboot” b. If HIVE Registry is “Manual Save To Flash”, click “Save and Reboot” Tips 1.
  • Page 84: Configuration For Winpac-5000-Ce7

    2.3.2.2. Configuration for WinPAC-5000-CE7 Calibration 1. Go to “System_Disk\Drivers\Serial_TOUCH\PenMount\BIN” and double click “calibrate.exe”. 2. Follow the instruction on the screen to begin calibration. 3. Once calibration has been completed, from the “Start” menu, click ”Programs”Open the “PAC Utility”: a. If HIVE Registry is “Auto Save Flash(Default)”, click “reboot” Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 84...
  • Page 85 b. If HIVE Registry is “Manual Save To Flash”, click “Save and Reboot” Changing the COM Port 1. Go to “System_Disk\Drivers\Serial_TOUCH\PenMount\BIN” and double click “SetCOM”. 2. In the pop-up dialog, select the COM Port you wish to use as default and click the “Set”...
  • Page 86 b. If HIVE Registry is “Manual Save To Flash”, click “Save and Reboot” 4. Disconnect the cable from the current COM Port and reconnect it to the specified COM Port. Simulating the Right Mouse Button 1. Go to “System_Disk\Drivers\Serial_TOUCH\PenMount\BIN” and double click “rbutton.exe”.
  • Page 87 4. The operation of the right mouse button can be simulated by repeating Step 2 and Step 3 for any object. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 87 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 88: Uninstalling Thewinpac-5000-Ce788

    2.3.2.3. Uninstalling theWinPAC-5000-CE7 The following procedure describes how to uninstall the PenMount serial touch driver. 1. Go to “System_Disk\Drivers\Serial_TOUCH\PenMount\BIN” and double click “Uninstall_Serial_Penmount.exe” 2. A warning pop-up will be displayed asking you to confirm the uninstall request. Click the “Yes” button to uninstall the driver. 3.
  • Page 89: Other Windows Ce7.0 Devices

    2.3.2.4. Other Windows CE7.0 Devices The driver for using with other windows CE7.0 devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 89 Copyright ©...
  • Page 90: Windows Xp Embedded

    2.4. Windows XP Embedded The touch driver for XP embedded is a universal driver. USB and Serial both use the same driver. 2.4.1. Universal Driver Two universal touch drivers are available. The first is for XP-8000 series modules of ICP DAS PAC controller, and the second is for other Windows XP embedded system. XP-8000 series: 1.Using ATOM CPU XP-8141-Atom/XP-8341-Atom/XP-8741-Atom...
  • Page 91: Installation For Xp-8000

    2.4.1.1. Installation for XP-8000 The following procedure describes how to install the PenMount universal touch driver. There is a RS-232 cable in the shipping package (Sec.1). The user can directly use this cable to connect the monitor with COM5 of XP-8000 to use universal touch driver to do a touch operation by serial way.
  • Page 92 TPM-4100_TP-4100/ For example: TP-5120/TP-6150/TP-7170 CD:\TP-2070\Driver\Win_XP_Embedded\XP-8000 device\ 2. Executing XPAC Utility to disable EWF on desktop. 3. Double click Setup.exe in the driver’s folder. 4. Click “Next” button to continue installation. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 92 Copyright ©...
  • Page 93 5. Click “I Agree” button. 6. Click “Install” button to install driver to destination folder. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 93 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 94 Tips & Warnings If a screen appears that shows “Found New Hardware Wizard”. Do not use this hardware wizard. Press Cancel. If a screen appears that shows “Hardware Installation”. Please press “Continue Anyway”. 7. Click “Finish” button. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 94 Copyright ©...
  • Page 95 8. Restart XP-8000. 9. Connect USB or serial cable to XP-8000(USB and serial can not be used simultaneously). If the USB or serial touch doesn’t work, please follow the steps below. a. From the “Start” menu, click “Programs””PenMount Universal Driver””PenMount Control Panel”. b.
  • Page 96 c. If search is successful, USB or serial touch driver has been installed. 10. Executing XPAC Utility to enable EWF on desktop. 11. Restart XP-8000. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 96 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 97 Tips 1. Appendix A  “A.2. Don’t plug USB cable when using serial touch driver” Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 97 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 98: Configuration For Xp-8000

    2.4.1.2. Configuration for XP-8000 Calibration 1. From the “Start” menu, click “Programs””PenMount Universal Driver” ”PenMount Control Panel”. 2. Check if the pattern “PenMount 6000 USB” or “PenMount 6000 RS232” shows. If yes, select a device and click “Configure” button. If no, refer to Sec.2.4.1.1. USB touch driver Serial touch driver 3.
  • Page 99 4. Executing XPAC Utility to disable EWF to save setting on desktop. 5. Restart XP-8000. 6. Executing XPAC Utility to enable EWF on desktop. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 99 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 100 7. Restart to XP-8000 for the changes to take effect. Change the COM Port For serial touch driver Method1: The touch driver will detect all com port to find what com port connects to serial touch screen monitor automatically when XP-8000 reboots every time. Method2: Please refer to the Step 9 of Sec.2.4.1.1 to detect again.
  • Page 101 3. Show a screen below (Left picture) Click the “mouse”  Turn into right picture. 4. Click any object: Click “My computer” to test if the “Right Button Icon” function work. If the screen below shows, the “Right Button Icon” function works.
  • Page 102: Uninstall For Xp-8000

    2.4.1.3. Uninstall for XP-8000 The following procedure describes how to uninstall the PenMount universal touch driver. 1. Executing XPAC Utility to disable EWF to start to save setting. 2. From the “Start” menu, click “Programs””PenMount Universal Driver” ”Uninstall”. 3. Click “Yes” button. 4.
  • Page 103 5. After reboot, executing XPAC Utility to enable EWF on desktop. 6. Restart XP-8000. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 103 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 104: Other Windows Xp Embedded Devices

    2.4.1.4. Other Windows XP Embedded Devices The driver for using with other windows XP Embedded devices can be obtained from the PenMount website to download the latest driver. We are use PenMount 6000 chip. PenMount website: http://www.salt.com.tw/en Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 104 Copyright ©...
  • Page 105: Windows Xp/7

    2.5. Windows XP/7 The touch driver for 2k/XP/2003/2008/Vista/7 is a universal driver. USB and Serial both use the same driver. 2.5.1. Universal Driver This section describes how to install, calibrate and uninstall the universal driver for 2k/XP/2003/2008/Vista/7. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 105 Copyright ©...
  • Page 106: Installation

    2.5.1.1. Installation The following procedure describes how to install the PenMount universal touch driver. 1. Copy the driver from the CD-ROM to your device. The touch driver can be obtained from: [name] Driver path TP-2070/TP-3080 CD:\[name]\Driver\Win_XP_7\ TPM-4100_TP-4100/ For example: TP-5120/TP-6150//TP-7170 CD:\TP-2070\Driver\Win_XP_7\ 2.
  • Page 107 6. Click “Install” button to install driver. 7. Click “Finish” to finish installation. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 107 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 108 Tips & Warnings When the system first detects a touch monitor, a screen appears that shows “Unknown Device”. Do not use this hardware wizard. Press Cancel. 8. If the USB or serial touch doesn’t work, following the steps below: a. From the “Start” menu, click “All Programs””PenMount Windows Universal Driver””Utility””PenMount Control Panel”.
  • Page 109 b. “Device” tabclick “Refresh” button to search USB or serial touch screen monitor if search is successful, “PenMount 6000 USB” or “PenMount 6000 RS232” will show. USB touch Serial touch c. If search is successful, the USB or serial touch driver has been installed.
  • Page 110 Tips 1. Appendix A  “A.2. Don’t plug USB cable when using serial touch driver” Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 110 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 111: Configuring

    2.5.1.2. Configuring Calibration 1. From the “Start” menu, click “All Programs””PenMount Windows Universal Driver””Utility””PenMount Control Panel”. 2. Check if the pattern ”PenMount 6000 USB” or “PenMount 6000 RS232” shows. If yes, select a device and click “Configure” button. If no, refer to Sec.2.5.1.1.
  • Page 112 Change the COM Port For serial touch driver Method1: The touch driver will detect all com port to find what com port connects to serial touch screen monitor automatically when PC reboots every time. Method2: Please refer to the Step 8 of Sec.2.5.1.1 to detect again. Simulating Right Mouse Button For details of how to configure right mouse button simulation, please refer to the process describes in “Simulating the Right Mouse Button”...
  • Page 113: Uninstall

    Uninstall 2.5.1.3. The following procedure describes how to uninstall the PenMount universal touch driver. 1. XP:StartAll ProgramsPenMount Windows Universal DriverUninstall. Win7: Control PanelProgramsPrograms and Features 2. Click “Next” button. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 113 Copyright ©...
  • Page 114 3. Click “Uninstall” button. 4. Click “Finish” button to reboot. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 114 Copyright © 2012 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com...
  • Page 115 Appendix A. Tips A.1. Don’t install USB and serial touch driver simultaneously in a device Platform: WP-8000/WP-5000/XP-8000-CE6 series contorller If USB and serial touch drivers are installed at the same time in a device, USB and serial touch drivers will conflict. Please install only one touch driver in a device every time.
  • Page 116 A.2. Don’t plug USB cable when using serial touch driver Platform : WP-8000/WP-5000/XP-8000-CE6 series controller Problem : Only serial touch driver is installed but both USB and RS-232 cables are plugged. Effect : RS-232 touch can’t work normally. Reason : The OS uses wrong USB driver and the driver conflicts with serial touch driver.
  • Page 117 1. Delete related description of TPM-6150 2. Add related description of TP-3080/TP-5120/TP-7170 3. There are two kinds of OSD menu. TP-4100/TPM-4100/TP-2070 use the same OSD menu. TP-3080/TP-5120/TP-6150/TP-7170 use the other one. 4. The OS version 1710 and upward of WP-8x4x supports resolution 640X480 for TP-2070.
  • Page 118 January 2015 “Power” to “PWR”. See the section 1.6.1 “System Configuration” 1. Add “weight” specification for 1.1.0 April 2015 TP-4100/TPM-4100 2. Add new Section 2.3 Windows CE 7.0 3. Modify Sec.2.1.1.4/2.1.2.4/2.2.1.4/2.2.2.4/2.4. 1.4. Touch Panel Monitor User Manual version 1.1.0, Last Revised: December 2015 Page: 118 Copyright ©...