Preparation before Operation
 Turn the breaker on
• After the power is turned on, the fl ap of the indoor unit opens and closes once to set the
reference position.
NOTE
 Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate
level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors
increases the cooling (heating) effect.
• Clogged air fi lters cause ineffi cient operation and waste energy. Clean them once in about
every 2 weeks.
 Please note
• The air conditioner always consumes 15-35W of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or
autumn, turn the breaker off.
• Use the air conditioner in the following conditions.
Mode
Operating conditions
COOL
Outdoor temperature: 10 – 46°C
Indoor temperature: 18 – 32°C
Indoor humidity: 80% max.
HEAT
Outdoor temperature: -15 – 24°C
Indoor temperature: 10 – 30°C
DRY
Outdoor temperature: 10 – 46°C
Indoor temperature: 18 – 32°C
Indoor humidity: 80% max.
• Operation outside this humidity or temperature range may cause a safety device to disable
the system.
8
Recommended temperature setting
For cooling: 26
For heating: 20
If operation is continued out of this range
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
• A safety device may work to stop the operation.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
28°C
24°C