LG LRGL5823 Series Owner's Manual page 60

Hide thumbs Also See for LRGL5823 Series:
Table of Contents

Advertisement

Available languages

Available languages

60 LIMITED WARRANTY
Problem
• Flames too big on
converted cooktop
(NP  LP)
• Flame is too small or
too large
• Gas smell
The cost of repair or replacement under the above excluded circumstances shall be borne by the
consumer.
TO OBTAIN WARRANTY SERVICE AND ADDITIONAL INFORMATION
Call 1-800-243-0000 and select the appropriate option from the menu.
Or visit our website at http://www.lg.com
Or by mail: LG Electronics Customer Service P.O. Box 240007 Huntsville, AL 35813 ATTN: CIC
Cause
The installer missed part of the conversion.
(Check 3 parts: regulator, cooktop nozzles,
broil/bake nozzles.)
cooktop nozzles
regulator
1. Variable gas pressure
2. Installer did not check
Center adjustment screw
Improper connection
Flexible Connector Hookup
Pressure
regulator
/
"
Adapter
1
2
Flex connector
(6 ft. max.)
/
1
2
broil/bake nozzles
/
1
" Adapter
2
Gas shut-off valve
"
1
/
" or
3
/
" Gas pipe
Adapter
2
4
Prevention
• Check with installer first
• Refer to installation manual
• Check with installer first
• Check with installer first

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents