Installing your Freestanding Cooker
Bringing it all together

Electrical connection

IMPORTANT: Electrical connections must be carried out by a suitably qualified person and in accordance with
all relevant local building and installation regulations.
Fitting on a Power Supply Cable
Connecting appropriate power supply ` terminal board/ connector block:
Using a screwdriver ,prize open tabs of the Terminal board cover.
Remove the wire clamp screw.
Fasten the wires beneath the corresponding screw heads, using brass 'bridge' for single phase supply.
Fasten cable clamp and close the cover of the terminal board.
The ac power supply should be 220-240 V, 50/60 Hz. For electric cookers, the minimum 45A fuse, or at
least 45A a distribution circuit breaker.
Connecting the supply cable to the mains
Install an approved circuit breaker with a minimum contact opening of 3 mm, between the appliance and the
mains fuse box .The circuit breaker should be sized according to the load and should comply with current
regulations (the earth wire should not be interrupted by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than 50℃with respect to
the room temperature, anywhere along its length Before switching fuse ON in meter-box check:
Earth continuity. The electrical safety of this appliance can only be guaranteed if the cooker is correctly
installed and earthed, in compliance with regulations on electrical installations.
The electrical capacity of the system and sockets will support the maximum power of the appliance, as
indicated on the data plate
If you require any technical guidance or find that your product is not operating as intended, a simple solution can often be found in the Troubleshooting section of these instructions,