1

Maintenance schedule

Service technician
(see the EnergyRite Service Manual for
instructions)
General:
• Address reported problems
• Inspect interior; clean and vacuum if
necessary
• Check for leaks (water, gas, and flue)
• Verify flue and air lines in good
condition and sealed tight
• Check control settings per the Access
Setup Menu in the EnergyRite Service
Manual
• Check ignition and flame sense
electrodes (sand off any deposits;
clean and reposition)
• Check wiring and connections
• Perform
performance verification per Section 9
in the EnergyRite Installation and
Operation Manual.
• Flame inspection (stable, uniform)
If combustion or performance
indicate need:
• Clean burners
• Clean heat exchanger
Follow the maintenance procedures given throughout this manual. Failure to perform the service and
⚠WARNING
maintenance or follow the directions in this manual could result in damage to the pool heater or system,
resulting in severe personal injury, death, or substantial property damage.
start-up
checkout
and
Owner maintenance
(see the following pages for instructions)
Daily
• Check pool heater area
• Check vent piping
• Check
Monthly
applicable)
• Check relief valve (if applicable)
• Test low water cutoff (if used)
Periodically
• Reset button (low water cutoff)
• Check pool heater piping (gas
and water) for leaks
Every
6 months
• Operate
applicable)
• Shut the pool heater down and
winterize if location is subjected
to freezing temperatures, see the
End
Winterizing
of season
EnergyRite Service Manual