Boiler Menu
The Boiler View displays various items regarding ignition, temperature monitoring, and modulation rates. As well
as software and hardware information.
Item
BOILER 1
BOILER 2
BOILER 3
BOILER 4
IGNITION
(IGNITION 1/2, models
1532-2342)
VENT WALL
LIMIT TEMP
EMS VDC
FIRE RATE
OUTLET MAX
OPERATOR
DIFF
PUMP POST
FLAME CUR
MASS
IDENTITY
IGN TYPE
ID CARD
SW ID
ERROR CODE
* Fixed values based on ID card
Application
Description
ALL
Enables Boiler for operation.
CASCADE
Enables Boiler for cascade operation.
CASCADE
Enables Boiler for cascade operation.
CASCADE
Enables Boiler for cascade operation.
IDLE=no CFH; PREP=pre-purge or inter-purge
between trials for ignition; IGN=trial for ignition;
BURN=burner operating; POST=post purge;
HARD=a hard lockout fault has occured requir-
ing manual high limit); and SOFT=a soft
ALL
lockout fault has occurred which interrupts the
manual high limit).
The CFH will resume after the soft lockout fault
has been corrected and a 15 min. waiting peri-
od has expired.
Not Available
Not Available.
ALL
Current Outlet -Limit temperature.
ALL
Current EMS signal in Volts DC.
ALL
PIM firing rate.
Defines Max Outlet temperature offset above
Target Setpoint (Press and hold up and down
H Mode 1,2,3
arrows for 3 seconds to enable adjustment),
see VERSA IC manual, catalog 5000.72.
ALL
Operator Potentiometer setting on PIM.
ALL
Current auto differential – Fixed by PIM.
ALL
Sets the length of the boiler pump purge.
ALL
Flame current in micro-amps (µA).
Thermal mass recovery, see VERSA IC manu-
ALL
al, catalog 5000.72.
Identifies the unit as boiler, water heater or
ALL
pool heater.
ALL
PIM Board type.
ALL
Identifies Raypak Identity Card.
ALL
PIM Software identification number.
ALL
Current Error Code.