Humidity; Cleanliness; Emi - H3C S12500R-2L Installation Manual

Switch router
Hide thumbs Also See for S12500R-2L:
Table of Contents

Advertisement

Temperature
Storage temperature

Humidity

Maintain appropriate humidity in your equipment room, as described in Table1-2.
Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical
property change of materials, and metal corrosion.
Lasting low relative humidity can cause washer contraction and ESD and cause problems
including loose mounting screws and circuit failure.
Table1-2 Humidity requirements
Humidity
Operating humidity
Storage humidity

Cleanliness

Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of
metal components and contact points. In the worst case, electrostatic adsorption can cause
communication failure.
Table1-3 Dust concentration limit in the equipment room
Substance
Dust particles
NOTE:
Dust particle diameter ≥ 5 µm
The equipment room must also meet limits on salts, acids, and sulfides to eliminate corrosion and
premature aging of components, as shown in Table1-4.
Table1-4 Harmful gas limits in the equipment room
Gas
SO
2
H
S
2
NH
3
Cl
2

EMI

All electromagnetic interference (EMI) sources, from outside or inside of the device and application
system, adversely affect the device in the following ways:
A conduction pattern of capacitance coupling.
Range
–40°C to +70°C (–40°F to +158°F)
Range
5% to 95%, noncondensing
5% to 95%, noncondensing
Concentration limit (particles/m
≤ 3 x 10
4
(No visible dust on desk in three days)
3
Max. (mg/m
)
0.2
0.006
0.05
0.01
1-3
3
)

Advertisement