5. When the 7036-P16 reboots, then the task is complete.
Replacing a 7036-P16
Attention: Before replacing a 7036-P16, create a 7036-P16 configuration file.
You need a Phillips screwdriver to replace this unit.
To replace a 7036-P16 unit, do the following steps:
1. Gather the following IP information for the 7036-P16 unit to be replaced:
v MAC Address: [MAC Address] (MAC Address label is on the back of the 7036-P16)
IP Address: [IP Address]
v
v Default Gateway: [IP Gateway Address]
v Name Server: [Name Server Address]
v Subnet Mask: [Subnet mask]
v Host Name: [Host Name]
v Domain Name: [Domain Name]
2. Power off the 7036-P16.
3. Remove the power cord.
4. Remove the Ethernet cable.
5. Remove each serial cable, and make sure each cable is marked indicating from which tty port it was
removed.
6. If the 7036-P16 is installed as a desktop unit, then remove the rubber feet from the plastic bag and
attach them to the replacement 7036-P16.
7. If the 7036-P16 is used as a rack mounted device, then undo the screws from the rack and remove
the 7036-P16 from the rack.
8. Remove the replacement 7036-P16 unit from the shipping package.
9. Remove the right angle brackets and screws from the plastic bag.
10. Use a Phillips screw to attach the brackets in the predrilled holes on the sides of the 7036-P16.
11. Mount the new 7036-P16 in the same location from which the previous 7036-P16 was removed.
12. Attach the power cord.
13. Attach the Ethernet cable.
14. Attach the serial cables, using the markings from Step 5 in order to restore each cable to its previous
port.
15. After the 7036 is configured on the network, telnet to the target 7036-P16. Type: telnet [IP Address
of target 7036-P16]
16. Log in as the root user.
17. To reconfigure the 7036-P16, type the following command:
cpconf fromhost=[Host Server IP Address]:/tmp/backup_[IP Address].txt

Field replacement units for the 7036-P16

Identify field replacement units (FRUs) for the 7036-P16.
The following table lists the FRUs for the 7036-P16.
Table 69. FRUs for the 7036-P16
Part number
80P6911
10N7714
Description
7036-P16 FRU
7036-P16 Software and Documentation CD. Form Number: LCD8-0170-01
107