Westinghouse WBRU 80W Series Installation, Start-Up And Maintenance Instructions page 9

Universal fire tube boiler
Hide thumbs Also See for WBRU 80W Series:
Table of Contents

Advertisement

DO NOT use spray paint, hair spray, or any other flammable spray near the boiler or near the exterior fresh air intake port. DO NOT
place any items in or around the exterior exhaust gas outlet port and/or fresh air inlet port that could restrict or block the flow in or out of
the vent system.
DO NOT store or place newspapers, laundry, or other combustible items near the boiler or the exterior exhaust gas outlet and/or fresh
air inlet port.
The owner should inspect the system monthly for damage, water stains, signs of rust, corrosion, and exhaust vent and air intake
blockage. If inspection of the unit shows signs of damage, the boiler should be shut off until the problem is repaired by a qualified
technician.
After installation, all boiler safety devices should be tested.
This boiler is certified for indoor installations only. The boiler consists of gas ignition system components which must be protected from
water (dripping, spraying, etc.) during operation and service. Carefully consider installation location and the placement of critical
components (circulators, condensate neutralizers, etc.) before installing the boiler.
DO NOT allow children to operate this unit. DO NOT use this unit if it does not appear to be operating correctly. A qualified technician
should service and inspect the boiler annually.
If the boiler is exposed to the following, do not operate until all corrective steps have been made by a qualified service technician:
1. FIRE
2. DAMAGE
3. WATER
This boiler is equipped with a three prong plug. It should only be plugged directly into a properly grounded three prong receptacle. DO
NOT remove the ground plug from the plug.
DO NOT alter or modify the boiler or boiler controls. This can be dangerous and WILL VOID the warranty.
Failure to follow these statements could result in property damage, severe personal injury, or death.
Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee.
This boiler provides a overheat shutdown limit. In the event the boiler water exceeds the set point of the control limit, the cutoff will trip
and the boiler will shut down. Certain local codes require additional temperature limits. In addition, certain types of systems may
operate at temperatures below the minimum set point of the limit provided with the boiler. Contact a qualified service technician for
additional overheat controls.
NOTE: When inquiring about service or troubleshooting, reference the model and serial numbers from the appliance rating label.
DO NOT USE THIS BOILER IF ANY PART HAS BEEN SUBMERGED IN WATER. Immediately call a qualified service technician. The
boiler MUST BE replaced if it has been submerged. Attempting to operate a boiler that has been submerged could create numerous
harmful conditions, such as a potential gas leakage causing a fire and/or explosion, or the release of mold, bacteria, or other harmful
particulates into the air. Operating a previously submerged boiler could result in property damage, severe personal injury, or death.
NOTE: Boiler damage due to flood or submersion is considered an Act of God, and IS NOT covered under product warranty.
Be sure to disconnect electrical power before opening boiler cabinet or performing service. Label all wires while performing service to
ensure proper re-wiring of the boiler. Wiring errors can cause improper or dangerous operation. Failure to do so could result in an
electrical shock, improper boiler operation, property damage, serious personal injury, or death.
Due to the low water content of the boiler, improper sizing of the boiler with regard to heating system load will result in excessive cycling
and accelerated component failure. Westinghouse DOES NOT warrant failures caused by improperly sized boiler applications. DO NOT
oversize the boiler to the system. Modular boiler installations greatly reduce the likelihood of boiler oversizing.
NOTICE
9
WHL-032 REV. 6.2.16

Advertisement

Table of Contents
loading

Table of Contents