Fluke DTX-GFM2 User Manual page 25

Fiber modules
Hide thumbs Also See for DTX-GFM2:
Table of Contents

Advertisement

Setting
SETUP > Fiber >
Index of Ref. Source (n)
> User Defined or
Default
SPECIAL FUNCTIONS >
Set Reference
Patch Lengths
(softkey on the View
Connections screen)
Settings for saving tests See the DTX Series CableAnalyzer Users Manual or Technical Reference Handbook for details on
Table 2. Fiber Test Settings (cont.)
The tester uses the index of refraction (n) defined in the currently selected fiber type (Default) or
a value you define (User Defined). The default value defined by the selected fiber type
represents the typical value for that fiber type. You may enter a different value if necessary. To
determine the actual value, change the index of refraction until the measured length matches
the known length of a fiber.
Increasing the index of refraction decreases the reported length.
Setting a reference sets the baseline power level for loss measurements. See "About Setting the
Reference" on page 11.
After you set the reference, you can enter the lengths of the reference test cords used. The
lengths are saved with results to meet TSB-140 reporting requirements for fiber test results.
preparing to save tests.
Description
Fiber Test Settings
19