Panasonic CS-XZ20XKEW-H Service Manual page 22

Table of Contents

Advertisement

Multi Split Combination Possibility:
A single outdoor unit enables air conditioning of up to four separate rooms for CU-4Z68TBE, CU-4Z80TBE.
o
A single outdoor unit enables air conditioning of up to five separate rooms for CU-5Z90TBE.
o
CONNECTABLE INDOOR UNIT
TYPE
1.6kW
CS-MZ16XKEW
CS-Z20XKEW
CS-XZ20XKEW
2.0kW
CS-XZ20XKEW-H
S-M20PY3E
CS-Z25XKEW
CS-XZ25XKEW
2.5kW
CS-XZ25XKEW-H
S-25PY3E
CS-Z35XKEW
CS-XZ35XKEW
3.5kW
CS-XZ35XKEW-H
S-36PY3E
4.2kW
CS-Z42XKEW
CS-Z50XKEW
5.0kW
CS-XZ50XKEW
S-50PY3E
6.0kW
S-60PY3E
7.1kW
CS-Z71XKEW
Capacity range of
connectable units
1 room maximum pipe length (m)
Allowable elevation (m)
Total allowable pipe length (m)
Total pipe length for maximum
chargeless length (m)
Additional gas amount over
chargeless length (g/m)
Remarks for CU-4Z68TBE / CU-4Z80TBE / CU-5Z90TBE
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor unit that will be connected to outdoor unit must be within connectable capacity range of
indoor unit. (as shown in the table above)
Example: The indoor units' combination below is possible to connect to CU-4Z80TBE. (Total nominal capacity of indoor units is between
4.5kW to 14.7kW)
1) Two CS-XZ25XKEW only. (Total nominal cooling capacity is 5.0kW)
Note: Above outdoor unit is contains and operates with refrigerant R32 gas.
CU-4Z68TBE
ROOM
A
B
C
From 4.5kW to 11.5kW
25
15
60
30
20
OUTDOOR UNIT
CU-4Z80TBE
D
A
B
C
From 4.5kW to 14.7kW
25
15
70
45
20
22
CU-5Z90TBE
D
A
B
C
From 4.5kW to 18.3kW
25
15
80
45
20
Note: "●" : Available
D
E