MIDI Data Format
1.2.14 Attack Time
This message adjusts the EG attack time that was specified by the sound data.
Control#
Parameter
73
Attack Time
Since this is a relative change parameter, it specifies an increase or decrease rela-
tive to 64. Increasing this value will make the attack more gradual, and decreas-
ing this value will make the attack sharper.
1.2.15 Brightness
This message adjusts the cutoff frequency of the low pass filter specified by the
sound data.
Control#
Parameter
74
Brightness
Since this is a relative change parameter, it specifies an increase or decrease rela-
tive to 64. Lower values will produce a more mellow sound.
For some sounds, the effective range may be less than the possible range of set-
tings.
1.2.16 Data Increment/Decrement (for RPN)
This message is used to increment or decrement values for parameters specified
by RPN (see 1.2.18), in steps of 1.
Control#
Parameter
96
RPN Increment
97
RPN Decrement
The data byte is ignored.
1.2.17 NRPN (Non-registered parameter number)
This is a message for setting the sound for things like vibrato, filter or EG. Use
NRPN MSB and NRPN LSB to specify the parameter that you wish to modify,
and then use Data Entry (see 1.2.4) to set the value for the specified parameter.
Control#
Parameter
98
NRPN LSB
99
NPRN MSB
If the Multi Part parameter Rcv NRPN = OFF, that part will not receive NRPN.
The following NRPN messages can be received.
NRPN
Data Entry*1
MSB
LSB
MSB
01H
08H
mm
01H
09H
mm
01H
0AH
mm
01H
20H
mm
01H
21H
mm
01H
63H
mm
01H
64H
mm
01H
66H
mm
*1 See 1.2.4
*2 "--" means that the set value will be ignored.
*3 Adjusts the time after the note is played until vibrato begins to take effect. The
effect will begin more quickly for lower values, and more slowly for higher
values.
1.2.18 RPN (Registered parameter number)
This message is used to specify part parameters such as Pitch Bend Sensitivity or
Tuning. Use RPN MSB and RPN LSB to specify the parameter that you wish to
modify, and then use Data Entry (see 1.2.4) to set the value of the specified
parameter.
Control#
Parameter
100
RPN LSB
101
RPN MSB
If the Multi Part parameter Rcv RPN = OFF, that part will not receive this mes-
sage.
24
PLG150-AP Owner's Manual / Bedienungsanleitung / Mode d'emploi
Data Range
0...64... 127
(-64...0...+63)
Data Range
0...64...127
(-64...0...+63)
Data Range
Data Range
0...127
0...127
Parameter Name and Data Range
LSB
-- *2
Vibrato rate
mm: 00H - 40H - 7FH (-64 ...0...+63)
--
Vibrato depth
mm: 00H - 40H - 7FH (-64 ...0...+63)
-- *3
Vibrato delay
mm: 00H - 40H - 7FH (-64 ...0...+63)
--
Low pass filter cutoff frequency
mm: 00H - 40H - 7FH (-64 ...0...+63)
--
Low pass filter resonance
mm: 00H - 40H - 7FH (-64 ...0...+63)
--
EG Attack Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
--
EG Decay Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
--
EG Release Time
mm: 00H - 40H - 7FH (-64 ...0...+63)
Data Range
0 ... 127
0 ... 127
The following RPN messages can be received.
RPN
Data Entry*1
MSB
LSB
MSB
LSB
00
00H
mm
--*2
Pitch bend sensitivity
mm: 00-18H (0...+24 semitones)
Specify up to 2 octaves in semitone steps
00
01H
mm
ll
Fine tuning
mm ll: 00H 00H -100 cents
mm 11: 40H 00H 0 cents
mm ll: 7FH 7FH +100 cents
Note: The next after mm 11: 00H 7FH (= -87.5) cent
is 01H 00H (= -87.4) cents.
00H
02H
mm
--
Coarse tuning
mm: 28H - 40H - 58H (-24...0...+24 semitones)
7FH
7FH
--
--
RPN Null
This empties settings from RPN and NRPN numbers.
Internal data is not affected.
*1 Refer to 1.2.4
*2 "--" means that the set value will be ignored.
1.2.19 Assignable controller
By assigning a control change number of 0...95 to a part, application of effects
can be controlled. This device allows two control change numbers (AC1 and
AC2) to be specified for each part.
The following parameters specify the effect of AC1 and AC2:
* Multi Part Parameter
1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH
The AC1 control change number is specified by the Multi Part parameter ACl
CONTROLLER NUMBER, and the AC2 control change number is specified by
the Multi Part parameter AC2 CONTROLLER NUMBER.
AC1, AC2, and AMPLITUDE CONTROL are processed on the host device (e.g.,
MOTIF ES, MU128, etc.)
1.3 Channel mode messages
These messages specify the basic operation of a part.
1.3.1 All Sound Off
This message silences all notes being played on the corresponding channel.
However, channel messages such as Hold 1 and Sostenuto will be maintained in
their present state.
Control#
Parameter
120
All Sound Off
1.3.2 Reset All Controllers
This message changes the settings of the following controllers.
Controller
Pitch bend
±0 (Center)
Channel pressure
0 (OFF)
Polyphonic key pressure
0 (OFF)
Modulation
0 (OFF)
Expression
127 (Max.)
Hold
0 (OFF)
Portamento
0 (OFF)
Sostenuto
0 (OFF)
RPN
Number unset, internal data is not affected.
NRPN
Number unset, internal data is not affected.
The following data is not changed.
Parameter values specified for program change, bank select MSB/LSB, volume,
pan, RPN and NRPN.
Control#
Parameter
121
Reset All Controllers
Parameter name and value range
:
:
:
:
Data Range
0
Value
Data Range
0

Hide quick links:

Advertisement