Panasonic AJHD3700B-PE Operating Instructions Manual page 148

Multi format digital hd video cassette recorder
Table of Contents

Advertisement

RF ENGINEER SET UP menu
The Conceal V warning sensitivity and warning display output are set on this menu.
Key
Key designation
F1
RED LAMP
F2
— —
F3
REMOTE
F4
SUPER
F5
ERR LOG
F6–F7
— —
F8
EXIT
F9–F13
— —
The underlining indicates the factory setting.
For selecting the lighting specifications for the red lamp on the
front panel. When this lamp is lighted, the superimposed warning
display, error log recording and remote output connectors
(RS-232C/RS-422/PARALLEL) are also linked.
LEVEL0: . . . (Setting for enhanced detection sensitivity: The red
lamp lights even when one error occurs.)
LEVEL1: . . . (Standard factory setting)
LEVEL2: . . . (Setting with slightly reduced detection sensitivity)
LEVEL3: . . . (Setting with further reduced detection sensitivity)
For selecting whether to output or mask the warning amber
information (CONCEAL_A, CONCEAL_V, HIGH_ERROR_RATE)
of the RS-232C, RS-422 and PARALLEL output connectors.
When the red lamp is lighted, the information is output regardless
of which setting has been selected for this item.
ACTIVE: When the amber warning lamp on the front panel is
lighted, the information is also output to the external
remote.
MASK:
Even when the amber warning lamp on the front panel
is lighted, the information is not output to the external
remote.
For selecting whether to output or mask the superimposed
warning amber information (CONCEAL_A, CONCEAL_V,
HIGH_ERROR_RATE). When the red lamp is lighted, the
information is output regardless of which setting has been
selected for this item.
ACTIVE: When the amber warning lamp on the front panel is
lighted, the superimposed information is displayed.
MASK:
Even when the amber warning lamp on the front panel
is lighted, the superimposed information is not
displayed.
For selecting whether to record the warning amber information
(CONCEAL_A, CONCEAL_V, HIGH_ERROR_RATE) in the
error log or mask it. When the red lamp is lighted, the information
is recorded in the error log regardless of which setting has been
selected for this item.
ACTIVE: When the amber warning lamp on the front panel is
lighted, the information is stored in the error log.
MASK:
Even when the amber warning lamp on the front panel
is lighted, the information is not stored in the error log.
For returning operation to the ENGINEER SET UP menu.