Specifications; Safety - HearthSense MO18HVL Manual

Vented natural gas logs
Table of Contents

Advertisement

Available languages

Available languages

Note: This vented appliance must be installed
only in a solid-fuel burning fireplace with a
working flue and constructed of noncombus-
tible material.
The charts indicate technical information
regarding the installation of your gas log set.
Minimum Vent Opening
Burner Orifice (Propane)**
* Btu/Hr Rating is the same when unit is converted to Propane gas.
** Number is printed on orifice.
Natural Gas
Propane Gas*
* For use if unit is converted to Propane gas.
* Add 4 in. when using on/off valve safety pilot kit
IMPORTANT: Read this owner's
manual carefully and completely
before trying to assemble, op-
erate, or service this heater.
Improper use of this heater can
cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
Only a qualified installer, service
agent, or local gas supplier may
install and service this product.
WARNING: Keep flue open
when operating unit.
200549-06B

SPECIFICATIONS

Model
Gas Type
BTU Input*
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
Minimum 5.5" W.C. Maximum 10.5" W.C.
Minimum 11" W.C.
MINIMUM FIREBOX SIZES
Front
Model
Width*
MO18HVL /
24"
CSW18HVL
MO24HVL /
28"
CSW24HVL
Please make sure that all of the specifications
shown are applicable before installation is
attempted.
The fireplace must include a working flue and
venting system with the minimum openings
shown as below.
MO18HVL /
CSW18HVL
Natural
45,000 BTU/Hr
8" Diameter
205
Maximum 13" W.C.
Back
Depth
Width *
18"
22"

SAFETY

Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness or nausea. If
you have these signs, the heater may not
be working properly. Get fresh air at once!
Have heater serviced. Some people are
more affected by carbon monoxide than oth-
ers. These include pregnant women, people
with heart or lung disease or anemia, those
under the influence of alcohol and those at
high altitudes.
Natural Gas: Natural gas is odorless. An
odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.
HearthSense
MO24HVL /
CSW24HVL
Natural
55,000 BTU/Hr
8" Diameter
225
Height
15"
18"
15"
18"
3

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Related Products for HearthSense MO18HVL

This manual is also suitable for:

Mo24hvlCsw18hvlCsw24hvl

Table of Contents