Download Print this page

Charging Indications; Troubleshooting - Pro Charging Systems 6013 Safety, Installation And Operating Instructions

Advertisement

Il est dangereux de travailler a proximité d'une batterie au plomb. Les batteries produisent des gaz explosifs en service
normal. Il est aussi important de toujours relire les instructions avant d'utiliser le chargeur et de les suivre à la lettre.

CHARGING INDICATIONS

When your battery charging system is activated, the battery status indicator provides charging information utilizing five red
LED indicators and one green LED indicator.
Indications are as follows:
ST
1
Amber LED . . . . . . . . . . .
ND
2
Amber LED . . . . . . . . . . . . . Illuminated configured for Gel Cell batteries
ST
1
RED LED . . . . . . . . . . . . . Charging - Initial Charging Up To 30%
ND
RD
2
& 3
RED LEDS . . . . . . . Charging - 60% Complete
ST
ND
RD
1
, 2
& 3
RED LEDS. . . . Charging - 90% Complete
BLINKING GREEN LED . . . .
STEADY GREEN LED . . . . . . Charge Complete –Float/Maintenance Mode-On for 5 minutes and off for 60 minutes
*We normally recommend our STANDARD Delta Volt profile for AGM Batteries. There are some cases where
particular AGM batteries are manufactured to different specifications and may need a special profile with a much
lower finish voltage limitation. In these cases we will do our best to accommodate your unique need.
The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the
batteries to be fully charged. The green LED will blink during the finishing stage of the charge cycle. After the completion of
the charge cycle, the green LED will remain on steady during the float-maintenance stage. During this final stage current
is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes.
Your system provides an equalization stage every 30 days while plugged in. If the charger is normally disconnected
from A/C after completing charge, equalization can be accomplished by plugging back into A/C whenever this stage
is desired. Battery manufacturers recommend that equalization is done once a month in order to further reduce
sulfation on the lead plates of a battery, which helps promote longer battery life. Note: During this process the
LEDs will go through their normal routine(Red LEDs counting up for % of charge along with the illuminated Red
LED Battery Type) and then the Green LED and Red Battery Type LED will blink) until the unit returns to the
maintenance mode and a steady Green LED and steady Red Battery Type LED. (Not applicable to Gel Profile)

TROUBLESHOOTING

PROBLEM: No LED indicators illuminated on battery status indicator.
Solution Sequence:
1. Confirm that current is being delivered to the charger. Use a meter or test light to check the AC power supply from its
source through all connecting points up to the charger.
2. Check that the AC circuit breaker (on front of the unit) is depressed.
3. Call technical support for further assistance (800.742.2740).
PROBLEM: The charge status indicator changes rapidly back and forth from red to green or the green LED will not
illuminate after excessive charging time (24 hours or more).
Solution Sequence:
1. Disconnect AC power from the charging system. This indication may signify a possible battery problem.
2. Call technical support for further assistance (800.742.2740).
Battery Type Indicators
Two amber LED indicators are provided in order to display what type of battery the
charger has been programmed to charge. NOTE: For information on reconfiguring
the battery type, please contact technical support (800.742.2740).
Battery System Percent Charged Indicators
Four LED indicators are provided in order to display the progress of the charge cycle
in percentage of charge.
Illuminated configured for Wet Cell and AGM* batteries
Finishing Stage (Note: Battery Type Indicator will also blink during this stage)
6

Advertisement

loading

This manual is also suitable for:

1212ob12251225ob24122412ob2420 ... Show all