Weil-McLain CG10 Specifications page 3

88 water & steam boilers – series 2 for gas, light oil, & gas/light oil – fired burners
Hide thumbs Also See for CG10:

Advertisement

Burner Specification & Data sheet — Beckett Gas Burners
Burner specifications and settings
Table 2
Gas train components and flame safeguards
Boiler
Model
Number
488R-488
588 & 688
788-988
1088R-1288
1388
Boiler
Model
OO or LFS
Number
488R-488
RM7897A
588-1388
--
Notes for Table 1 and Table 2
1.
Standard motor voltage is 120/60/1 for CG10, CG25 , and
230/60/1 for CG50.
2.
Direct Spark Ignition is standard on all models.
3.
CG10 models are available only as OO (On-Off operation) or
LFS (Low fire start, high fire run. Single position air, adjust-
able opening gas valve).
4.
CG25 and CG50 are available as: LHL Low-high-low-off
operation. Two position air controlled by linkageless damper
actuator, fixed damper pre-purge.
Must be wired with boiler temperature or pressure control
switch or operation will be low-high-off.
MOD – On-off operation with proven low fire start and
full modulating firing conditions with combustion air
control.
Modulation control drives combustion air damper and
fuel metering valve in response to boiler demand. Fixed
damper pre-purge for RM 7897C.
Open damper pre-purge for RM7840L.
5.
Burner capacities listed for elevations up to 2,000 feet. For
higher elevations, consult local Weil-McLain distributor/
agent or sales office.
6.
Gas ratings based on natural gas with heating value of 1,000
btu per cubic foot and specific gravity of 0.60.
7.
Boiler-burner unit to be adjusted to achieve +0.10 inches
W.C. pressure at flue collar, resulting in positive pressure in
firebox as listed.
Part No. 550-142-027/0508
Standard Gas Control Components and Sizes in Inches
Manual
Hand Valve
(Field Gas Train
Operating Gas Valve
Connection)
1
1-1/4
1-1/2
2
2-1/2
Flame Safeguard Provided with Listed Control Systems by Code
UL/ CSD1
LHL
MOD
OO or LFS
--
--
RM7897A
RM7897C
RM7840L
Additional control suppliers are available
Combination
Diaphragm
And Regulator
1
1-1/4
1-1/2
2
2-1/2
FM
LHL
MOD
--
--
--
RM7897C
RM7840L
8.
Minimum gas pressures listed are subject to variations due
to job conditions. Gas burners for other gas pressures are
available. Consult local Weil-McLain distributor/agent or
sales office.
9.
Gas manifold pressures shown are for initial start-up. Final
pressure should be determined after checking actual gas flow
and combustion readings.
10.
Combustion Controls:
a.
RM7897 flame safeguard control uses ultraviolet elec-
tronic flame detector to monitor gas burner flame, and
provides pre-purge programming. "C" models provide
10 second main flame establishing period.
b.
RM7840L flame safeguard control monitors the gas
burner flame, provides pre-purge and post-purge pro-
gramming, provides switching necessary to allow firing
rate motor to be driven to both low fire start and high fire
positions, prevents start-up if preignition interlock circuit
or running interlock circuit does not "prove", system will
lock out on safety. Ultraviolet sensitive electronic flame
detector is standard.
11.
Burners listed by Underwriters Laboratories, Inc., Canadian
Gas Association, state of Connecticut, Fire Marshal state of
Massachusetts, city of New York MEA, and others.
12.
Special controls can be provided to meet other code require-
ments not listed. Consult your local Weil-McLain distributor/
agent or sales office.
(continued)
Safety
Manual Checking
Gas Valve
Gas Valve
1
1-1/4
1-1/4
1-1/2
1-1/2
2
2-1/2
2-1/2
IRI
OO or LFS
LHL
RM7897A
--
--
RM7897C
1
2
MOD
--
RM7840L