5-3. Cooling Capacity

Indoor Unit
MCAV77C5
Outdoor Unit
GRV77L5
240V Single Phase 50Hz
RATING CAPACITY
AIR FLOW RATE
EVAPORATOR
ENT. TEMP. °C
W.B.
D.B.
15
17
19
21
23
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
2.10 kW
430 m
OUTDOOR AMBIENT TEMP. °C
20
TC
2.12
CM
0.45
21
SHC
1.53
23
SHC
1.74
25
SHC
1.96
27
SHC
2.12
29
SHC
2.12
31
SHC
2.12
TC
2.27
CM
0.46
21
SHC
1.30
23
SHC
1.52
25
SHC
1.74
27
SHC
1.95
29
SHC
2.17
31
SHC
2.27
TC
2.42
CM
0.48
21
SHC
1.07
23
SHC
1.29
25
SHC
1.51
27
SHC
1.72
29
SHC
1.94
31
SHC
2.15
TC
2.56
CM
0.49
23
SHC
1.06
25
SHC
1.27
27
SHC
1.49
29
SHC
1.71
31
SHC
1.92
TC
2.72
CM
0.50
25
SHC
1.03
27
SHC
1.24
29
SHC
1.46
31
SHC
1.68
3
/h
CONDENSER
25
30
35
2.02
1.93
1.84
0.49
0.52
0.56
1.48
1.44
1.40
1.70
1.66
1.61
1.92
1.87
1.83
2.02
1.93
1.84
2.02
1.93
1.84
2.02
1.93
1.84
2.17
2.07
1.97
0.50
0.53
0.57
1.26
1.22
1.17
1.48
1.43
1.39
1.69
1.65
1.61
1.91
1.87
1.82
2.13
2.07
1.97
2.17
2.07
1.97
2.31
2.21
# 2.10
0.51
0.55
0.59
1.03
0.99
0.94
1.24
1.20
1.16
1.46
1.42
1.38
1.68
1.63
1.59
1.89
1.85
1.81
2.11
2.07
2.03
2.45
2.34
2.23
0.53
0.57
0.61
1.01
0.97
0.93
1.23
1.19
1.14
1.45
1.40
1.36
1.66
1.62
1.58
1.88
1.84
1.79
2.60
2.48
2.34
0.54
0.58
0.62
0.99
0.94
0.89
1.20
1.16
1.11
1.42
1.38
1.33
1.64
1.59
1.54
21
40
45
1.73
1.59
0.62
0.68
1.34
1.28
1.56
1.50
1.73
1.59
1.73
1.59
1.73
1.59
1.73
1.59
1.86
1.71
0.63
0.69
1.12
1.06
1.34
1.28
1.55
1.49
1.77
1.71
1.86
1.71
1.86
1.71
1.97
1.82
0.65
0.71
0.89
0.83
1.11
1.05
1.33
1.26
1.54
1.48
1.76
1.70
1.97
1.82
2.09
1.93
0.67
0.73
0.88
0.82
1.10
1.03
1.31
1.25
1.53
1.47
1.75
1.68
2.19
2.03
0.69
0.75
0.84
0.79
1.06
1.01
1.28
1.23
1.49
1.44

Advertisement