Object Removal Detection - HIKVISION iDS-9600NXI-I8/8F(B) Series User Manual

Hide thumbs Also See for iDS-9600NXI-I8/8F(B) Series:
Table of Contents

Advertisement

3)
Click Draw Region and draw a quadrilateral in the preview window by specifying four vertexes of the
detection region.
Step 7 Set the arming schedule. Refer to Chapter 11.1 Configure Arming Schedule.
Step 8 Set the linkage actions. Refer to Chapter 11.2 Configure Alarm Linkage Actions.
Step 9 Click Apply.

12.8 Object Removal Detection

Purpose:
Object removal detection function detects the objects removed from the pre-defined region, such
as the exhibits on display, and a series of actions can be taken when the alarm is triggered.
Step 1 Go to System > Event > Smart Event.
Step 2 Select a Camera to configure.
Step 3 Click Object Removable.
Step 4 Check Enable Object Removable Detection.
Step 5 Optionally, check Save VCA Picture to save the captured pictures of object removable
detection.
Step 6 Follow the steps to set the detection rules and detection areas.
1)
Select an Arming Region to configure. Up to 4 regions are selectable.
2) Drag the sliders to set Time Threshold and Sensitivity.
Network Video Recorder User Manual
Figure 12-8 Object Removal Detection
134