Vinotemp VT - PONYKEG Owner's Manual page 8

Vinotemp pony-size kegerator owner's manual
Table of Contents

Advertisement

If there is still a small drip from the faucet, you may have tightened the plastic lever
too much and may need to unscrew silver snug counter-clockwise (as shown in Figure
2) one turn. That should correct the problem if exists.
Figure 1
Installing the CO
2
Install the CO
2
the hose barb connection on the CO
two self-locking black plastic snap-on clamps. Use pliers (not supplied) to snap the
clamp on tightly to ensure that there are no leaks.
Insert a special washer (provided with the kit) into the regulator to the cylinder
attachment nut.
Attach the CO
screwing the regulator nut onto the cylinder valve
and tightening with an adjustable wrench.
Remove the bolt with the nut from the cylinder
retainer. Using two screws attach it inside the unit
on the left side of the back wall. (Holes are pre-
drilled and screws are included)
Slide the cylinder through the retainer and secure it
with the bolt and the nut. Position the cylinder in a
way that you would be able to read the numbers on
the gauges and easily access shut-off valves.
WARNING: CO
gas can be dangerous; CO
2
gas which can be hazardous if not handled properly. Make sure you READ and
UNDERSTAND the following procedures for CO
1. ALWAYS connect the CO
explosion with possible death or injury when the cylinder valve is opened.
2. NEVER connect the CO
3. ALWAYS follow correct procedures when cylinders are changed.
4. ALWAYS secure the cylinder in an upright position.
5. NEVER drop or throw a CO
6. ALWAYS keep a CO
(preferably 70°F). Securely fasten with a chain in an upright position when storing.
7. ALWAYS ventilate and leave the area immediately if CO
8. ALWAYS check the D.O.T. test date on the cylinder neck before installation. If over
five (5) years, do not use, return cylinder to gas supplier.
9. NEVER connect a product container unless there are two (2) safety's in the
pressure system:
a. One at or on the CO
b. One at or on the product coupler or in the pressure gas line.
8
Figure 2
Regulator and CO
Cylinder
2
gas line tube to the regulator by attaching one end of the red tube to
2
regulator to the CO
2
cylinder to a regulator. Failure to do so could result in
2
cylinder directly to the product container.
2
cylinder.
2
cylinder away from heat. Store extra cylinders in a cool place
2
regulator
2
W W W . V I N O T E M P . C O M
regulator. Secure the tube by using one of the
cylinder by
2
cylinders contain high-pressure compressed
2
cylinders BEFORE INSTALLATION.
2
leakage has occurred.
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vvtt--ffuullllkkeeggVt-ponykeg

Table of Contents