Fireplace Dimensions - Majestic fireplaces UVC36 Homeowner's Installation And Operating Manual

Vermont castings vent-free gas room heaters homeowner's installation and operating manual
Table of Contents

Advertisement

Majestic Fireplaces
UVC / UVS Vent-Free Heaters
®
36"
25¹⁄₂"
36"
51"
34¹⁄₄"
Electrical Cable
Knockout 1" Dia.
Gas Line Access 2" Dia.
Fig. 1 UVC/UVS36 specifications and framing.
44"
31"
44"
62¹⁄₄"
Electrical Cable
Knockout 1" Dia.
Gas Line Access 2" Dia.
Fig. 2 UVC/UVS43 specifications and framing.
4
UVC/UVS36 Vent Free Room Heater
Rough
Opening
Depth
14¹⁄₂"
Rough
Opening
Height
34³⁄₄"
Outside
Air
8¹⁄₂"
5¹⁄₂"
UVC/UVS43 Vent Free Room Heater
Rough
Opening
Depth
16¹⁄₂"
Rough
Opening
Height
37¹⁄₂"
Outside
37"
Air
8¹⁄₂"
5¹⁄₂"
20"
Rough Opening Width 36¹⁄₂"
33"
36"
0135
UVC/S36 Specs
9/7/00 djt
31"
Rough Opening Width 43¹⁄₂"
40"
43"
0135
UVC/S43 Specs
9/7/00 djt
Finished Wall
Thickness
21"
32³⁄₄"
5³⁄₄"
3¹⁄₄"
1"
4"
7³⁄₄"
9"
Finished Wall
Thickness
35¹⁄₂"
23¹⁄₂"
7"
3³⁄₄"
1"
4"
8¹⁄₄"
12¹⁄₂"
Gas Line
Access 2" Dia.
Electrical Cable
Knockout 1" Dia.
Electrical Box
Knockout 2" Dia.
2"
0135
Gas Line
Access 2" Dia.
Electrical Cable
Knockout 1" Dia.
Electrical Box
Knockout 2" Dia.
2"
0135
20000135