Majestic fireplaces UVC36 Homeowner's Installation And Operating Manual

Vermont castings vent-free gas room heaters homeowner's installation and operating manual

Advertisement

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND US-
ING APPLIANCE.
IMPORTANT: Read all instruc-
tions and warnings carefully be-
fore starting installation. Failure
to follow these instructions may
result in a possible fire hazard
and will void the warranty.
WARNING: If the information
in this manual is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline
or other flammable vapors and
liquids in the vicinity of this or
any other appliance.
— What to Do If You Smell Gas
Do not try to light any appli-
ance.
Do not touch any electrcal
switch; do not use any phone
in your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas
supplier, call the fire depart-
ment.
— Installation and service must
be performed by a qualified
installer, service agency or the
gas supplier.
This is an unvented gas-fired
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combus-
tion and ventilation air must be
provided. Refer to Page 4.
Vent-Free Gas Room Heaters
Models: UVC36 / UVS36
UVC43 / UVS43
Homeowner's Installation and

Operating Manual

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
GF454
UVC Cover
2/27/97
20000135 9/05 Rev. 4

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces UVC36

  • Page 1: Operating Manual

    Provisions for adequate combus- tion and ventilation air must be provided. Refer to Page 4. Vent-Free Gas Room Heaters Models: UVC36 / UVS36 UVC43 / UVS43 Homeowner's Installation and Operating Manual INSTALLER: Leave this manual with the appliance.
  • Page 2: Table Of Contents

    Cleaning the Standing Pilot Control System ... 14 Cleaning Catalytic Filters (UVC Only) ... 14 Replacement Parts ... 15 Optional Accessories Fan Kit ... 17 Hard (Direct) Wire Hook Up ... 17 Remote Controls ... 17 Ceramic Refractory Panels ... 17 Arched Door Front ...
  • Page 3: Installation & Operating Instructions

    Installation & Operating Instructions This gas room heater should be installed by a qualified installer in accordance with local building codes and with current Na- tional Fuel Gas Code. ANSI Z223.1/NFPA 54. "This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air".
  • Page 4: Fireplace Dimensions

    Majestic Fireplaces UVC / UVS Vent-Free Heaters ® UVC/UVS36 Vent Free Room Heater 36" 25¹⁄₂" 36" 51" Outside 34¹⁄₄" Electrical Cable Knockout 1" Dia. Gas Line Access 2" Dia. Fig. 1 UVC/UVS36 specifications and framing. UVC/UVS43 Vent Free Room Heater 44"...
  • Page 5: Safety Devices

    It is recommended that you burn your Vermont Castings Majestic Products fireplace for a least six (6) hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time.
  • Page 6: Mantels

    Majestic Fireplaces UVC / UVS Vent-Free Heaters ® Mantels Depending on the width of the mantel it may be in- stalled higher or lower from the combustion chamber opening. This also applies to the distance between the mantel leg (if installed) and the fireplace. Refer to Fig- ures 3a and 3b for correct mounting heights and widths for combustible mantels and mantel legs.
  • Page 7: Gas Specifications

    Millivolt Hi/Lo UVS43RN Natural Millivolt Hi/Lo UVS43RP Propane Millivolt Hi/Lo UVC36 / UVS36 / UVC43 / UVS43 Certified To ANSI Z 21.11.2a-2003 Unvented Room Heaters Units: B42A00, B42B00, D42A00, D42B00, B41AS0, B41BS0, D41AS0, D41BS0 Gas Inlet and Manifold Pressures Natural Minimum Inlet Pressure 5.5"...
  • Page 8: Electrical Connection

    Any electrical re-wiring of this fan must be done by a qualified electrician. Whether wiring directly to the fan junction box or into the EB1 (electrical receptacle box, P/N ZA1200) first ensure cable is secured using box connector.
  • Page 9: Alternate Switch Location

    2. Attach wire to switch and install switch into recep- tacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. (Fig. 10) ON/OFF Switch Fig. 10 Remote switch wiring. FP382 Alternate Switch Location REMOTE SWITCH WIRING - NVC 11/20/96 Remote switch can be installed on either side of the access door.
  • Page 10: Operating Instructions

    Majestic Fireplaces UVC / UVS Vent-Free Heaters ® Glass Information (UVC Only) Only glass approved by CFM Specialty Home Products should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. •...
  • Page 11: Ember Material Placement

    UVC/UVS36 LOGS 9/8/00 djt Fig. 17 Correct pilot flame pattern. LG132 UVC36/UVS43 UVC43/UVS43 Fig. 18 Approximate flame heights for each model. Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge them- selves of this air.
  • Page 12: Lighting And Operating Instructions

    Majestic Fireplaces UVC / UVS Vent-Free Heaters ® Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 13: Troubleshooting Gas Control (Nova Sit 820)

    Nova SIT 820 START • Gas Supply On Pilot Lights with Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner System OK 20000135 Majestic Fireplaces Troubleshooting CHECK • Supply line hooked up • Shutoff valve open • Lockout has engaged. Wait 60 seconds and try again •...
  • Page 14: Maintenance

    The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint. Cleaning the Standing Pilot Control System The burner and control system consists of: •...
  • Page 15 UVC/UVS36 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVC/UVS 36/43 Vent Free Heaters Ref. Description Log Set Complete Log Front Left Log Front Right...
  • Page 16: Replacement Parts

    Bracket CO Catalyst Holder Remote Switch Remote Switch Kit (Not Shown) O.S.A. Assy Contact CFM Specialty Home Products for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fire- places distributor or dealer. You will need the following information when ordering replacement parts: 1.
  • Page 17: Optional Accessories

    Take care when handling the refractory panels as they are fragile until held in place and supported. The arched door front kit is designed to visually en- hance the appearance of the UVC36 fireplace only. DV36ADKP DV36ADKA UVC / UVS Vent-Free Heaters ®...
  • Page 18: Decorative Frame Trim

    UVC/UVS43 DV43GTP/DV43GTA DV43TKP/DV43TKA DV43KMP/DV43KMA DV43KWP/DV43KWA Decorative Bay Window Available for the UVC36 only. When fitting the Bay Window Kit, the original front frame/glass assembly MUST remain in place. The Bay Window Kit is fitted over the existing front glass. Installation 1.
  • Page 19: Warranty

    All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
  • Page 20 CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com...

This manual is also suitable for:

Uvc43Uvs36Uvs43

Table of Contents