Fan Kit

FK24 Fan Assembly
Fan specifications: 120 volt, 60 Hz, .75 Amps
This fan does not need regular maintenance, however
periodic cleaning is required. Check the area under the
control door and in front of the fan and wipe or vacuum
at least once a month during the operating season.
Should this fan require servicing, the power supply
must be disconnected.
The FK-24 comes with the electrical cord attached.
1. Slide fan assembly from the left side into the fire-
place opening, line up mounting holes with screw
studs on back of fireplace and fasten with #10-24
hex nuts.
2. Install thermal sensor on bottom of firebox using
#10-24 hex nuts.
3. (Option A) - Place electronic fan speed control box
on bottom of fireplace base, lining up mounting holes
with screw studs. Fasten fan speed control box with
#10-24 hex nuts.
(Option B) - The speed control can be installed in
an electrical box at normal wall switch height for
convenient access.
4. The power supply may be connected in 2 ways:
Method A - route the 6' (1.8m) lead fitted to the unit
to a conveniently located wall socket.
Method B - If the EB-1 receptacle box (Pt.
#ZA1200) was correctly connected when the unit
was installed, the fan lead can be directly plugged
into the EB-1 plug socket.
5. Whether wiring directly to the fan junction box, (Op-
tion A) or into the EB-1 (Option B), first ensure cable
is secured using box connector.
The fireplace, when installed must be electrically
connected and grounded in accordance with local
codes or, in the absence of local codes, with the
current CSA C22.1 Canadian Electrical Code or for
US installations, follow local codes and the National
Electrical Code, ANSI/NFPA No. 70.
Hard (Direct) Wire Hook-Up
First connect the ground wire to the ground stud located
on the base of either box. Black wire from supply
should connect to the variable speed switch. Alternate
speed switch wire connects to temperature sensor. Al-
ternate lead from sensor connects to fan. Alternate fan
lead connects back to the white supply wire. (Fig. 20)
20000135

Optional Accessories

Fig. 20 FK-24 wiring.
Optional remote control units are available to control
different functions of the appliance.
Ceramic refractory panels are available to line the fire-
box area.
Take care when handling the refractory panels as they
are fragile until held in place and supported.
The arched door front kit is designed to visually en-
hance the appearance of the UVC36 fireplace only.
Majestic Fireplaces
UVC / UVS Vent-Free Heaters
®
Any electrical rewiring of this fan must be
completed by a qualified electrician.
Turn off all power before hook-up.
Temperature
Sensor
Speed
Control
Black
White
Ground
FP394
WIRING DIAGRAM

Remote Controls

11/20/96
Model
Function(s) Controlled
MRC1
ON/OFF
MRC2
ON/OFF and Temperature
MRC3
ON/OFF and Temperature control
with a digital and a programmable
24 hour clock
IMT
Wall mounted thermostat control

Ceramic Refractory Panels

Unit
UVC36
UVS36
UVC43
UVS43

Arched Door Front

DV36ADKP
Polished Brass
DV36ADKA
Antique Brass
Fan
FP394
Kit Model
UV36CR
UV36CR
UV43CR
UV43CR
17