JP5: Watchdog Timer Active Type Setting
Options
Active NMI
System Reset (default)
Disabled Watchdog Timer
The following sample programs show how to Enable, Disable and
Refresh the Watchdog Timer:
;----------------------------------------------------------------------------------
; Enter the WDT function mode, interruptible double-write
;----------------------------------------------------------------------------------
MOV
DX, 2EH
MOV
AL, 87H
OUT
DX, AL
OUT
DX, AL
MOV
DX, 2EH
MOV
AL, 07H
OUT
DX, AL
MOV
DX, 2FH
MOV
AL, 08H
OUT
DX, AL
MOV
DX, 2EH
MOV
AL, F5H
OUT
DX, AL
MOV
DX, 2FH
MOV
AL, 80H
OUT
DX, AL
MOV
DX, 2EH
MOV
AL, F7H
OUT
DX, AL
MOV
DX, 2FH
MOV
AL, 00H
OUT
DX, AL
MOV
DX, 2EH
MOV
AL, F6H
OUT
DX, AL
MOV
DX, 2FH
MOV
AL, 00H
OUT
DX, AL
;---------------------------------------------------------------------------------
; Exit extended function mode
;---------------------------------------------------------------------------------
MOV
DX, 2EH
MOV
AL, AAH
OUT
DX, AL
* User can also use AL, 00H's defined time for reset purposes,
e.g.00H for Disable, 01H = 1sec, 02H = 2sec.....FFH = 255sec
Settings
1
Short 1-2
Short 2-3
Open
; select CRF0
; * 00H=Disabled
2
3
21