Safety Precautions; Power Connections; Ground Connections - Yaesu MARK-V FT-1000MP Operating Manual

Vertex standard operating manual hf transceiver mark-v ft-1000mp
Hide thumbs Also See for MARK-V FT-1000MP:
Table of Contents

Advertisement

Before initiating the installation of your MARK-V FT-
1000MP transceiver, please take the time to review
the following safety guidelines.
P
C
OWER
We strongly recommend that AC power for your
MARK-V FT-1000MP be provided only from the sup-
plied FP-29 AC Power Supply, so as to ensure that the
voltage and current requirements of the MARK-V FT-
1000MP are fully met.
If you do need to provide DC power to your MARK-
V FT-1000MP, on an emergency basis, from a power
source other than the FP-29, please be absolutely cer-
tain to observe proper connections in your wiring. Note
that other manufacturers may use the same type of
DC power connector as does Yaesu, but the wiring con-
figuration of the other manufacturer's plug will almost
certainly be different from that specified for your trans-
ceiver. The correct wiring diagram is shown below.
G
C
ROUND
The MARK-V FT-1000MP HF transceiver, like any
other HF communications apparatus, requires an ef-
fective ground system for maximum electrical safety
and best communications effectiveness. A good ground
system can contribute to station efficiency in a number
of ways:
r It can minimize the possibility of electrical shock to
the operator.
r It can minimize RF currents flowing on the shield of
the coaxial cable and the chassis of the transceiver;
such currents may lead to radiation which can cause
interference to home entertainment devices or labo-
ratory test equipment.
r It can minimize the possibility of erratic transceiver/
accessory operation caused by RF feedback and/
or improper current flow through logic devices.
An effective earth ground system make take sev-
eral forms; for a more complete discussion, see an
appropriate RF engineering text. The information be-
low is intended only as a guideline.
MARK-V FT-1000MP Operating Manual
ONNECTIONS
ONNECTIONS
S
AFETY
Typically, the ground connection consists of one or
more copper-clad steel rods, driven into the ground. If
multiple ground rods are used, they should be posi-
tioned in a "V" configuration, and bonded together at
the apex of the "V" which is nearest the station loca-
tion. Use a heavy, braided cable (such as the discarded
shield from type RG-213 coaxial cable) and strong
cable clamps to secure the braided cable(s) to the
ground rods. Be sure to weatherproof the connections
to ensure many years of reliable service. Use the same
type of heavy, braided cable for the connections to the
station ground bus (described below).
Inside the station, a common ground bus consist-
ing of a copper pipe of at least 25 mm (1") diameter
should be used. An alternative station ground bus may
consist of a wide copper plate (single-sided circuit board
material is ideal) secured to the bottom of the operat-
ing desk. Grounding connections from individual de-
vices such as transceivers, power supplies, and data
communications devices (TNCs, etc.) should be made
directly to the ground bus using a heavy, braided cable.
Do not make ground connections from one electri-
cal device to another, and thence to the ground bus.
This so-called "Daisy-Chain" grounding technique may
nullify any attempt at effective radio frequency ground-
ing. See the drawing below for examples of proper
grounding techniques.
Inspect the ground system – inside the station as
well as outside – on a regular basis so as to ensure
maximum performance and safety.
Besides following the above guidelines carefully,
note that household or industrial gas lines must never
be used in an attempt to establish an electrical ground.
Cold water pipes may, in some instances, help in the
grounding effort, but gas lines represent a significant
explosion hazard, and must never be used.
P
RECAUTIONS
page 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents