6) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overflow into the drain pan. Allow to soak
for 10 minutes.
Note: If there is excessive scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block flow. Pour additional cleaning
solution over the extruding head until the evaporator assembly is completely full.
7) Remove the grille and spout.
8) Scrub the inside of the ice storage bin, inside of the bin top, the agitator, drip ring, ice
chute area, spout, grille, and the inside of the drain pan using a nylon scouring pad,
brushes, and cleaning solution. Rinse all parts thoroughly with clean water.
NOTICE! Be sure to keep the micro switch mounted on the bin top dry.
9) If you placed a clamp on the reservoir hose in step 6, remove it before operation.
10) Move the control switch to the "ICE" position. Replace the air filter, louver, drip ring,
agitator, bin top, and panels in their correct positions.
11) Plug the appliance into the electrical outlet. Move the power switch to the "ON" position.
Make ice using the solution until the appliance stops making ice.
12) Move the power switch to the "OFF" position, then remove the louver and air filter. Move
the control switch to the "DRAIN" position, then move the power switch to the "ON"
position. Allow the water system to drain completely.
13) Move the power switch to the "OFF" position, then unplug the appliance from the
electrical outlet.
14) Remove the front panel, top panel, and bin top.
15) Pour clean, warm water into the ice storage bin and melt any remaining ice. Remove the
agitator and drip ring. Rinse the inside of the ice storage bin, the agitator, and drip ring
thoroughly with clean water.
16) Pour clean, warm water over the extruding head until the evaporator assembly and the
reservoir are full and the water starts to overflow into the drain pan. Plug the appliance
into the electrical outlet, then move the power switch to the "ON" position. Allow the
water system to drain completely.
Note: If you do not sanitize the icemaker, move the power switch to the "OFF" position
after the water system drains. Unplug the appliance from the electrical outlet, then
replace the drip ring, grille, and spout in their correct positions. Go to step 10 in
"III.B.1.e) Sanitizing Procedure - Final."
17) Move the power switch to the "OFF" position, then unplug the appliance from the
electrical outlet.