0 to +-200v amplitude, 350 khz bandwidth high-voltage function generator and variable-gain linear amplifier with ieee 488.2 and rs-232 control (39 pages)
0 to ±400v amplitude, 50 khz bandwidth high-voltage function generator and variable-gain linear amplifier with ieee 488.2 and rs-232 control (40 pages)
0 to ±200v amplitude high-voltage function generator and variable-gain linear amplifier with ieee 488.2 and rs-232 control (44 pages)
Summary of Contents for Avtech AV-143CP-PS-AVA
Page 1
FAX: 800-561-1970 (USA & Canada) or +1-613-686-6679 (Intl) OTTAWA, ONTARIO U.S.A. 13669-0265 CANADA K2C 3H5 info@avtechpulse.com http://www.avtechpulse.com/ INSTRUCTIONS MODEL AV-143CP-PS-AVA 0 to +2V IN, 0 to +12V OUT, 500 mA 0.4 us RISE TIME DC-COUPLED LINEAR AMPLIFIER SERIAL NUMBER: ____________...
Avtech product is found to be defective, Avtech shall at its option repair or replace said defective item. This warranty does not apply to units which have been dissembled, modified or subjected to conditions exceeding the applicable specifications or ratings.
TABLE OF CONTENTS WARRANTY........................2 TECHNICAL SUPPORT....................2 TABLE OF CONTENTS....................3 INTRODUCTION.......................5 SPECIFICATIONS........................5 REGULATORY NOTES.....................6 FCC PART 18.......................... 6 EC DECLARATION OF CONFORMITY...................6 DIRECTIVE 2002/95/EC (RoHS).....................7 DIRECTIVE 2002/96/EC (WEEE)....................7 AC POWER SUPPLY REGULATORY NOTES................8 INSTALLATION.........................9 VISUAL CHECK........................9 POWER RATINGS........................9 CONNECTION TO THE POWER SUPPLY................9 PROTECTION FROM ELECTRIC SHOCK................10 ENVIRONMENTAL CONDITIONS..................11...
INTRODUCTION Model AV-143CP-PS-AVA is a customized DC-coupled fixed-gain linear amplifier, with a gain (V ) of +6 V/V. The input may range from 0 to +2V. The input impedance is 1 kΩ. The corresponding output voltages are 0 to +12V. The maximum output current is +500 mA.
If interference is observed, check that appropriate well-shielded cabling is used on the output connectors. Contact Avtech (info@avtechpulse.com) for advice if you are unsure of the most appropriate cabling. Also, check that your load is adequately shielded. It may be necessary to enclose the load in a metal enclosure.
Directive 2002/96/EC categories 1-7 and 10, as stated in the "Article 2 - Scope" section of Directive 2002/95/EC. DIRECTIVE 2002/96/EC (WEEE) European customers who have purchased this equipment directly from Avtech will have completed a “WEEE Responsibility Agreement” form, accepting responsibility for WEEE compliance (as mandated in Directive 2002/96/EC of the European Union and local laws) on behalf of the customer, as provided for under Article 9 of Directive 2002/96/EC.
AC POWER SUPPLY REGULATORY NOTES This instrument converts the AC input power to the DC voltage that powers the internal circuitry of this instrument using a Tamura AAD130SD-80-A switching power supply. According to the manufacturer, the Tamura AAD130SD-80-A has the following certifications: UL60950-1 IEC60950 -1...
INSTALLATION VISUAL CHECK After unpacking the instrument, examine to ensure that they have not been damaged in shipment. Visually inspect all connectors, knobs, and handles. Confirm that a power cord and an instrumentation manual (this manual), are with the instrument. If the instrument has been damaged, file a claim immediately with the company that transported the instrument.
5. Do not attempt any repairs on the instrument, beyond the fuse replacement procedures described in this manual. Contact Avtech technical support (see page 2 for contact information) if the instrument requires servicing. Service is to...
ENVIRONMENTAL CONDITIONS This instrument is intended for use under the following conditions: 1. indoor use; 2. altitude up to 2 000 m; 3. temperature 5 °C to 40 °C; 4. maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C;...
FUSES This instrument contains four fuses. All are accessible from the rear-panel. Two protect the AC prime power input, and two protect the internal DC power supplies. The locations of the fuses on the rear panel are shown in the figure below: Fuses #1 and #2 Fuse #4 Fuse #3...
DC FUSE REPLACEMENT The DC fuses may be replaced by inserting the tip of a flat-head screwdriver into the fuse holder slot, and rotating the slot counter-clockwise. The fuse and its carrier will then pop out. FUSE RATINGS The following table lists the required fuses: Recommended Replacement Part Nominal Fuses...
FRONT PANEL CONTROLS 1. POWER Switch. This is the main power switch. When turning the instrument on, there may be a delay of several seconds before the instrument appears to respond. 2. OVERLOAD Indicator. When the instrument is powered, this indicator is normally green, indicating normal operation.
REAR PANEL CONTROLS 1) AC POWER INPUT. An IEC-320 C14 three-pronged recessed male socket is provided on the back panel for AC power connection to the instrument. One end of the detachable power cord that is supplied with the instrument plugs into this socket.
GENERAL INFORMATION BASIC CONTROL The AV-143CP-PS-AVA is a DC to >500 kHz fixed-gain linear amplifier. The gain is fixed at +6 V/V. The required voltage input signal is applied at the “IN” connector. This mode is illustrated below: ARBITRARY WAVEFORM,...
Page 17
caused by the cabling and the cable's capacitance will distort the output signal and degrade the rise and fall times, particularly if the signals with fast rise times are used.
2) Set the signal generator to produce a +2V, 10 kHz waveform. (The input impedance of the AV-143CP-PS-AVA is 1 kΩ). Connect a cable from the SYNC connector of the signal generator to the TRIG input of an oscilloscope. Set the oscilloscope to trigger externally.
Page 19
5) Turn on the amplifier and the signal generator. 6) The Channel B waveform should increase to +12V, and have a shape similar to that of the Channel A waveform. 7) This completes the operational check.
There are no user-adjustable internal circuits. For repairs other than fuse replacement, please contact Avtech (info@avtechpulse.com) to arrange for the instrument to be returned to the factory for repair. Service is to be performed solely by qualified service personnel.
MAINTENANCE REGULAR MAINTENANCE This instrument does not require any regular maintenance. On occasion, one or more of the four rear-panel fuses may require replacement. All fuses can be accessed from the rear panel. See the “FUSES” section for details. CLEANING If desired, the interior of the instrument may be cleaned using compressed air to dislodge any accumulated dust.
WIRING DIAGRAMS WIRING OF AC POWER M a in s c i r c u it s - h a z a r d o u s li v e . D o n o t a t te m p t a n y r e p a i r s o n t h i s i n s t r u m e n t b e y o n d t h e f u s e r e p la c e m e n t p r o c e d u r e s d e s c r i b e d i n t h e m a n u a l .
PCB 158P - LOW VOLTAGE POWER SUPPLY, 1/3 X 1 3 6 - 3 2 1 / 4 " S S S C R E W , 0 6 0 4 M P P 1 8 8 6 - 3 2 S S E X T T O O T H W A S H E R , 0 6 W E 1 8 8 X 1 4 6 - 3 2 1 / 4 "...
PCB 158P - LOW VOLTAGE POWER SUPPLY, 2/3 D i g i W K 6 2 3 2 - N D F U S E H O L D E R X 2 1 P C B 1 5 8 A L , V 2 B R A C K E T 6 4 0 4 4 5 - 6 , D i g i A 1 9 7 3 - N D T P 6 T P 3...