place the UPS away from other units at least 20 cm to avoid interference. DO NOT operate the UPS
where the temperature and humidity is outside the specific limits. (Please check the specs for the
limitations.)
Plug in the AC input cord to the wall outlet. For the best results,
suggest charging the battery at least 4 hours before initial use. The
unit charges its battery while connecting to the utility.
Plug in the loads to output receptacles on the rear panel of the UPS.
Simply turn on the power switch of UPS unit, then devices
connected to the UPS will be protected by UPS unit.
To surge protect a network connection, connect a network cable from the wall jack outlet to the IN
jack of the UPS. Then connect a network cable from the OUT jack of the UPS to the network
device.
UPS equipped with communication port allows monitoring and controlling from computer screen.
Connect one end of a communication cable to your PC and the other to the com port at the rear of
the UPS.
ViewPower is an UPS power management software, allowing users to control and monitor UPS
straightly from PC monitor. Insert ViewPower software CD or download ViewPower software from
http://www.power-software-download.com
complete the software installation.
After computer is restarted, ViewPower is geared and presents as an orange plug icon located in
the system tray at the right-bottom corner.
To turn on the UPS, press power switch lightly. To turn off the UPS, please press power switch
again.
!
"
#
PC615N-650 and PC615N-850 UPS are equipped with Green Power Function. For saving power
and protecting battery, the method of deep discharging protection is adopted on inverter mode.
www.redeal.pt
to your hard drive. Follow on-screen instructions to
Trouble-shooting
Use the table below to solve minor problems. If any abnormal situations occur that are not listed
above, please call service technician for assistance.
Problem
Possible Cause
No LED display on
Low battery.
the front panel.
Battery fault.
The UPS is not turned on.
Alarm continuously
The UPS is overload.
sounds when the
mains is normal.
When power fails,
The UPS is overload.
back-up time is
Battery voltage is too low.
shortened.
Battery defect. It might be due to high
temperature operation environment, or
improper operation to battery.
The mains is normal,
Power cord is loose.
but LED blinks..
Specifications
Model
650
650VA/
CAPACITY
360W
INPUT
Voltage
Voltage Range
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
Type & Number
12V/7AHx1
Charging Time
PHYSICAL
Dimension, DxWxH, (mm)
287x100x142
Net Weight (kgs)
4.25
Environment
Humidity
Noise Level
MANAGEMENT
USB
Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008
* Product specifications are subject to change without further notice.
Re
Deal
Solutions
Charge the UPS at least 6 hours.
Replace the battery with the same type of
battery.
Press the power switch again to turn on the
UPS.
Remove some loads first. Before reconnecting
equipment, please verify that the load matches
the UPS capability specified in the specs.
Remove some critical load.
Charge the UPS at least 6 hours.
Replace the battery with the same type of
battery.
Reconnect the power cord properly.
850
1000
1500
850VA/
1000VA/
1500VA/
480W
600W
900W
110/120 VAC or 220/230/240 VAC
81-145 VAC / 162-290 VAC
+/-10%
Typical 2-6 ms, 10 ms max.
Simulated Sine Wave
12V/9AHx1
12V/7AHx2
12 V/9 AH x 2
4-6 hours recover to 90% capacity
350x146x 160
397x146x205
4.90
8.0
11.1
0-90 % RH @ 0-40° C (non-condensing)
Less than 40 dB
2000
2000VA/
1200W