1 Warning Caution: • Pb free solder has a higher melting point that standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a soldering iron with temperature control and adjust it to 750 ± 20°F (400 ± 10°C). In case of using high temperature solder- ing iron, please be careful not to heat too long.
Page 4
3.2. Trial Operation (After Checking Troubleshooting Guide) 3.2.1. Assembly • Confirm if there is no gap between Housing A and B by pinching lead wires or power cord. • Confirm if the slide terminal cover moves smoothly. • Confirm if 4 screw caps are attached to a housing B. 3.2.2.
4 Disassembly and Assembly Instructions * Please assemble by opposite procedure. 4.1. How to remove screw caps and screws of housing A and B 4.2. How to remove the connector for module and slide battery terminal and the LED PCB...
Page 6
4.3. How to remove the terminal base 4.4. How to remove the terminal base from the housing A...
Page 7
4.5. How to remove a Fuse 4.6. How to remove the module from the housing B...
Page 8
4.7. How to remove the power cord from the module...
Page 12
Model No. : EY0L82 Parts List Ref. Safety Part No. Part Name & Description Q'ty Remarks WEY0L82K4158 HOUSING A ASSEMBLY WEY0L82L2109 MAIN PCB ASSEMBLY WEY0L80L2618 FUSE 1 (250V 3.15A) WEY6230L6017 TAPPING SCREW 5 (2.6*8) WEY0L82K3029 HOUSING B WEY0L82K3020 HOUSING B 1 (Only for Oceania) WEY0217K6236 TORX TAPPING SCREW...