POWER The Progeny CRYSTAL controller should be connected to a 24 Hour 220/240V mains supply. Ideally a fused spur should be used for this purpose. The cable used to connect the mains supply should be 0.75 to 2mm fused terminal block is provided for mains.
Page 3
Supply current for internal electronics and charging batteries. For Crystal controllers this is reserved as 1.25A. For Crystal .net this is reserved as 1.5A. Lock Loads (Magnets, Strikes etc.) Auxiliary loads. (Readers, Keyboards, Indicators & Sounders) CONNECTING 24V LOCKS To operate a 24V lock a customer supplied 24V PSU will be required.
Page 4
CONTROLLERS TWO DOOR VERSION 40028 The "two door" version simply contains two access controllers in one enclosure. Both controllers can be programmed from the keyboard but first the user needs to choose which controller to programme. 40027 To select control panel A (or door 1) press the [#] and [1] key together.
Page 5
P2V4 CONTROLLER Controller Status LED Reset Push Button Controller ID Keyboard Lock Supply Terminal Relay B 40027 Lock O/P Keyboard Signals Reader A Inputs Reader B Outputs RS 485 Interlock Network Ethernet Network End of Line Interface Option Link 0V to Earth Link Document Number: MAN0049 Issue: 4.01...
USER MENU The User Menu is access by entering * followed by the User Password. The default for this is 654321. Users Menu # Description Default Value * 00 User Password 6 5 4 3 2 1 * 01 Access Code None * 02 Discover Presented Cards...
Page 7
ADDING CARDS by PRESENTATION (DISCOVER) User function 02 Make sure you have the correct reader technology selected for the readers that are connected before using this function. All cards presented to the reader will be remembered and given access. Related User Menus: ...
Page 8
ADDING CARDS by NUMBER Adding or enabling credentials by entering can be useful when the credentials themselves are not available or if a large number of credentials need to be added. Single card: Note that some cards have a serial number printed on them.
Page 9
DISABLING CARDS by NUMBER Single card If a card is reported lost or stolen, the card can be disabled to remove the security risk without affecting any other card users. Block of cards Enter User Password * 6 5 4 3 2 1 The quickest way to disable a whole group Status LED will Flash of cards is to use the “block add”...
ENGINEERS’ MENU Engineers Menu # Description Range Default Value * 00 Password 000000 to 999999 1 2 3 4 5 6 * 01 Delay to Lock Release 0 to 99 Sec * 02 Lock Release Duration 0 to 99 Sec * 03 PDO Time 0 to 99 Sec...
Page 11
Crystal Reader Native Crystal Bidirectional 4 wire Interface ISO 15693 ISO 15693 (Tagit 64) (Firmware V4.30+) Progeny Prox Standard Progeny HID format for Prox & iCLASS Biometric Connects to most Biometric Readers Progeny 26 bit Progeny Extended 26 bit Wiegand...
RELAY B MODE Relay B can be configured to perform a number of different roles. By default the relay simply mimics the lock relay and allows loads to be driven or provide voltage free contacts for other equipment such as Barriers, Turnstiles etc.
Page 13
IP ADDRESS & GATEWAY ADDRESS Programming the IP ADDRESS Programming the GATEWAY ADDRESS Enter Engineers Password * 1 2 3 4 5 6 Status LED will Flash Select IP Address menu * 8 0 Enter value 192*168*0*56 Complete & Exit Programming Mode Status LED will stop Flashing NETMASK Programming the NETMASK...
Page 14
CRYSTAL CONTROLLER USING USB ADAPTER Lock Proximity Reader Proximity Reader 485 Network to next controller EMERGENCY DOOR RELEASE USB Adaptor Touch Switch Server / Client PC Keyboard LOCK DEVICE BACK E.M.F SUPPRESSION It is important to check that the locking device is suppressed. Any electromagnetic device will produce a back E.M.F when power is removed.
Page 15
CRYSTAL.NET CONTROLLER USING ETHERNET Cables: Cable Twisted Strands Core Strand Conductor Resistance Cores Screened Function Pair per Core Thickness Area per 100m 9.2Ω Readers 0.2mm 0.22mm² 9.2Ω Keyboards 0.2mm 0.22mm² 9.2Ω Network 0.2mm 0.22mm² 4Ω Locks 0.2mm 0.50mm² Document Number: MAN0049 Issue: 4.01 Page 15 of 16...
Page 16
Date: 16-10-2014 Firmware Version Number: 4.82 and Later EMC & LV Certificate Number WEEE Certificate Number 17851 WEE/JG2915VS Copyright BSB Electronics Ltd TA Progeny Access Control 2014 All rights reserved. Document Number: MAN0049 Issue: 4.01 Page 16 of 16...
Need help?
Do you have a question about the P2V4 and is the answer not in the manual?
Questions and answers