AC Pro  S Series User Manual
Hide thumbs Also See for AC Pro S Series:

Advertisement

Quick Links

AC Pro S-Series 30-36K
User Manual
Models
AWH30LB-D3DNA3D/I
AWH30LB-D3DNA3G/O
AWH30QF-D3DNB4K/I
AWH30QF-D3DNB2K/O
AWH36LB-D3DNA3D/I
AWH36LB-D3DNA3G/O
AWH36QF-D3DNB4O/I
AWH36QF-D3DNB2O/O
(Refrigerant R410A)

Advertisement

Table of Contents
loading

Summary of Contents for AC Pro AC Pro S Series

  • Page 1 AC Pro S-Series 30-36K User Manual Models AWH30LB-D3DNA3D/I AWH30LB-D3DNA3G/O AWH30QF-D3DNB4K/I AWH30QF-D3DNB2K/O AWH36LB-D3DNA3D/I AWH36LB-D3DNA3G/O AWH36QF-D3DNB4O/I AWH36QF-D3DNB2O/O (Refrigerant R410A)
  • Page 3: Function And Control

    1. Function and Control 1.1 Remote Controller Introduction Introduction for icons on display screen Introduction for buttons on remote controller Note: After putting through the power, the air conditioner will give out a sound. Operation indicator “ “ is ON ...
  • Page 4 1. On/Off Button Press this button can turn on or turn off the air conditioner. After turning on the air conditioner, operation indicator “ “ on indoor unit’s diplay is ON (green indicator. The colour is different for different models), and indoor unit will give out a sound.
  • Page 5 7. SLEEP Button Under COOL, HEAT or DRY mode, press this button to start up sleep function. " " icon is displayed on remote controller. Press this button again to cancel sleep function and " " icon will disappear. 8. TEMP Button By pressing this button, you can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor unit's display.
  • Page 6: Function Introduction For Combination Buttons

    Function introduction for combination buttons 1. Enery-Saving Function Under cooling mode, Press "TEMP" and "CLOCK" buttons simultaneously to start up or turn off energy-saving function. When energy-saving function is started up, "SE" will be shown on remote controller, and air conditioner will adjust the set tempera- ture automatically according to ex-factory setting to reach to the best energy-saving effect.
  • Page 7: Brief Description Of Modes And Functions

    1.2 Brief Description of Modes and Functions Service Manual 1. Temperature Parameters  Indoor Preset Temperature (PRESET) 6.2 Brief Description of Modes and Functions  Indoor ambient temperature (AM) 1. emperature Parameters 2. Basic Functions Once energized in no case should the compressor be restarted within 3 minutes of start. In the situation that Indoor preset temperature ( preset memry function is available for the first energization and the compressor is at a stop before de-energization the...
  • Page 8 Service Manual  Protection protection is the same as that under cooling mode. Protection ② Protection is the same as that under the cooling mode. 6. Heating Mode Working conditions and process of heating (3) Heating Mode -If Tamb. Tpreset +3.6 F, the unit enters heating mode, in which case the four way valve, the compressor and the Working conditions and process of heating ①...
  • Page 9  Under Auto mode, if Tamb. T preset +1.8 F is detected, the unit will select to run under cooling mode, in which case implicit preset temperature is 77 F; if Tamb. T preset -1.8F, the compressor will stop, the outdoor fan will stop with a time lag of 1 minute, and the indoor fan will run at preset speed;...
  • Page 10 F. Faults of temperature Sensors Designation of sensors Faults The sensor is detected to the open-circuited or Indoor ambient temperature short-circuited for successive 5 seconds The sensor is detected to the open-circuited or Indoor tube temperature short-circuited for successive 5 seconds The sensor is detected to the open-circuited or Outdoor ambient temperature short-circuited for successive 30 seconds...
  • Page 11: Care And Cleaning

    CARE AND CLEANING W RNING Take notice of the following items before cleaning your Livo indoor wall unit. • To avoid electric shock or injury, do not attempt to clean the unit unless it has been turned off and the indoor and outdoor units have been disconnected from the main power supply. •...
  • Page 12: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE/SOLUTION System does not restart. Cause: The system has a built-in three-minute delay to prevent short and/or rapid cycling of the compressor. Solution: Wait three minutes for the protection delay to expire. Indoor unit emits unpleasant odor Cause: Typically unpleasant odors are the result of mold or mildew forming on when started the coil surfaces or the air filter.
  • Page 13 TROUBLESHOOTING PROBLEM CAUSE/SOLUTION Water leaking from the indoor Cause: While it is normal for the system to generate condensate water in cooling unit into the room. mode, it is designed to drain this water via a condensate drain system to a safe location. Solution: If water is leaking into the room, it may indicate one of the following.
  • Page 14: Energy Saving Tips

    ENERGY SAVING TIPS 1. Reduce room setpoint at night: During the nighttime hours you don't require the same level of conscious cooling or heating. Try using Sleep Mode to gradually relax room temperature and allow the unit to run less and save energy. 2.

Table of Contents