Requirement: The drain pump is
empty. → Page 45
Because water may remain in the
1.
drain pump, remove the pump cap
carefully.
Clean the inside and the thread on
2.
the pump cap and pump housing.
Make sure that the impeller in the
3.
drain pump can be turned.
Replace the pump cap.
4.
Make sure that the components of
the pump cap are securely seated.
Cleaning and servicing en
Screw on the pump cap.
5.
90°
The handle on the pump cap must
be in a vertical position.
Insert the maintenance flap and
6.
lock it into place.
1
Close the maintenance flap.
7.
Cleaning the water outlet hose at
the siphon
If the water outlet hose at the siphon
is dirty or the detergent solution is
not being pumped out, you must
clean these.
Switch off the appliance.
1.
Disconnect the appliance's mains
2.
plug from the power supply.
Loosen the hose clamp and care-
3.
fully remove the water outlet hose.
2