Mitsubishi Electric MSZ-FH12NA Service Manual page 17

Hide thumbs Also See for MSZ-FH12NA:
Table of Contents

Advertisement

(5) Press
button to turn the weekly timer ON. (
•When the weekly timer is ON, the day of the week whose timer setting is complete, will light.
Press
button again to turn the weekly timer OFF. (
NOTE:
The saved settings will not be cleared when the weekly timer is turned OFF.
2. Checking weekly timer setting
2. Checking weekly timer setting
(1) Press
button to enter the weekly timer setting mode.
*
blinks.
(2) Press
or
buttons to view the setting of the particular day or number.
(3) Press
button to exit the weekly timer setting.
NOTE:
When all days of the week are selected to view the settings and a different setting is included among them,
displayed.
8-9. i-see CONTROL ( ) MODE
In the i-see control mode, the room temperature is controlled based on the sensible temperature.
(1) Press SENSOR button with a thin instrument during COOL, DRY, HEAT and AUTO mode to activate i-see control mode ( ).
The default setting is "active".
(2) Press SENSOR button again to activate ABSENCE DETECTION ( ).
(3) Press SENSOR button again to release i-see control mode.
ABSENCE DETECTION ( )
This function automatically changes the operation to energy-saving operation when nobody is in the room.
(1) To activate this function, press SENSOR button until
i-see control mode.
(2) Press SENSOR button again to release ABSENCE DETECTION.
NOTE:
Any person at the following places cannot be detected:
• Along the wall on which the air conditioner is installed
• Directly under the air conditioner
• Where any obstacle, such as furniture, is between the person and the air conditioner
A person may not be detected in the following situations:
• Room temperature is high.
• A person wears heavy clothes and his/her skin is not exposed.
• A heating element of which temperature changes signifi cantly is present.
• Some heat sources, such as a small child or pet, may not be sensed.
• A heat source and the air conditioner are more than 20 ft. (6 m) apart.
• A heat source does not move for a long time.
OBH683D
lights.)
goes out.)
appears on the operation display of the remote controller during the
17
will be

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz-fh09naMsz-fh06naMsz-fh15naMsz-fh18naMsz-fh18na2

Table of Contents