SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS WARNING: RISK OF ELECTRICAL SHOCK Safety precautions should always be used when operating this or any electrical appliance. Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the warnings below.
Sweep debris into a plastic bag and dispose of properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of old lamp(s). To order a replacement lamp, call 800.875.8577 or go to www.envion.com. Mercury Notice...
MAIN PARTS Locking Latch 2. Air Inlet Grill 3. Permanent HEPA-Type Filter: the permanent filter removes small visible and non-visible particles. 4. UV Lamp Cover 5. Control Panel 6. Control Dial: 3 fan speed settings: (Low, Medium and High). 7. UV/VOC Button 8.
OPERATING THE THERAPURE TPP230H ® Before using the Therapure air purifier, please read the following important information. ® Electrical Ratings: • 120V Setting: 120Vac, 60 Hz • Power consumption: 55 watts (0.5 ampere) at high fan speed, • 3 watt UV light lamp •...
Replace the filter if the filter ® has a tear or a hole in it. If the filter is damaged or needs replacement, please visit the Therapure website at ® www.envion.com to order for a replacement filter. Or call 800.875.8577. TPP230H...
OPERATING THE THERAPURE TPP230H ® CONTROLS/SETTINGS: Power Control – To operate the Therapure air purifier, turn the knob clockwise to turn on. ® Speed Control – The Therapure has three different speeds of cleaning, LOW, MED and HI. ® Turn the knob ONCE for LOW, TWICE for MED and THIRD for HI. UV Control –...
CLEANING & MAINTENANCE Keep the Therapure 230H functioning properly by cleaning the permanent HEPA-Type filter every ® four weeks. More frequent cleaning will be necessary if the unit is located in an area with a high level of airborne contaminants (excessive amounts of smoke, pet dander, etc.). Exposing the Therapure 230H to candle/oil/fireplace soot and smoke is not recommended and will ®...
For maximum effectiveness, please replace the UV bulb annually. If the lamp stops functioning or needs replacement, please visit our web site at www.envion.com to order a replacement lamp. Or call 800.875.8577. Caution: • Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness of the lamp.
CLEANING & MAINTENANCE Before replacing the UV lamp, make sure the Therapure air purifier is turned ® off and unplugged. Let the lamp cool down for 5 minutes before replacing it. Replacing the UV Lamp: Release the inlet grill by pressing on the locking latch (see diagram of Main Parts). 2.
TROUBLESHOOTING PROBLEM REASON SOLUTION Unit will not Power button has not been Press the Power button. operate turned on. Unit is unpugged. Check to ensure unit is plugged in. The inlet grill has not been Check to make sure filter and inlet installed &...
ARBITRATION AGREEMENT PLEASE READ THIS AGREEMENT CAREFULLY. YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT(S) SHIPPED IN CONNECTION WITH THIS AGREEMENT (THE “PRODUCTS”) FOR MORE THAN THIRTY (30) DAYS AFTER RECEIPT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, YOU MAY RETURN THE PRODUCT TO COMPANY WITHIN THIRTY (30) DAYS OF RECEIPT FOR A FULL REFUND.