MAIN PARTS environments. We want you to be fully satisfied with your Allergy Pro™ 200. OPERATING THE AllERGY PRO 200 AIR PURIFIER ™ That’s why your Allergy Pro™ 200 comes with a one-year limited warranty. Getting Ready Operation Once you’ve experienced the purity of Controls/Settings Allergy Pro™ 200 air, visit us at our website to find out more ways to improve MAINTENANCE the quality of your air and your life with our premium products and upgrades. Filter Replacement Cleaning External Surfaces Please be sure to read the following instructions carefully to ensure optimal TROUBlE-SHOOTING performance and safety. www.envionproducts.com ONE-YEAR lIMITED WARRANTY ARBITRATION AGREEMENT Allergy Pro™ by Envion, LLC P.O. Box 9159 Van Nuys, CA 91409-8291 800.875.8577 AP200...
sAfety instructions sAfety instructions READ AND SAVE THESE INSTRUCTIONS » Do not operate this product with a damaged cord or plug. Discard the product or return to an authorized service facility for examination and/or repair. WARNING: RISK OF ElECTRICAl SHOCK » Never use the power cord to pick up, carry, drag, pull, or lift the Allergy Pro 200 air purifier. Do ™ Safety precautions should always be used when operating this or any electrical appliance. not pull the cord against or around sharp corners and edges. This could result in injury to the Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the user or damage to the cord. warnings below. » Always remove the plug from its power outlet by holding onto the plug itself and pulling gently. Use only as described in this Allergy Pro ™ 200 manual. To reduce the risk of electric shock, do » not attempt to service the product in any way other than in the manner described in the Never pull on the cord itself to unplug it from its power outlet. “Cleaning & Maintenance” section of this manual. » Use care when operating the Allergy Pro ™ 200 air purifier by keeping all foreign objects, fingers, body parts, hair, loose clothing and jewelry away from openings.
Product benefits mAin PArts » 1. locking latch Air purification: 2. Air Inlet Grill 1. True HEPA filter takes particles out of the air, purifying it. 3. True HEPA Filter: Captures at least 99.7% of allergens and irritants that pass through the filter down to 0.1 microns. » Effectively removes smoke, pollen, dust, 4. Control Dial: Off, HI, MED, LOW animal dander, dust mites, mold and bacteria. 5. Air Outlet Grill »...
Page 5
oPerAting the Allergy Pro oPerAting the Allergy Pro ™ ™ Before using the Allergy Pro 200 air purifier, please read the following important information. Safety ™ Electrical Ratings: 1. Do not place near fans. • 120V Setting: 120Vac, 60 Hz 2. Keep both sides of the unit at least 1 foot away from a wall. • Power consumption: 55 watts (0.5 ampere) at high fan speed, 3 Do not place the unit near curtains. 4. Placing the unit close to the source of air pollution is an effective way to improve • Net weight: 8.7 lbs indoor air quality. • Dimension (L x W x H): 8.8” x 6.9” x 25.5” Replacement Parts: Filter – AP200FA Locate a level surface on which to place the Allergy ™ 200 air purifier near a 120V outlet (follow warnings in the “SAFETY INSTRUCTIONS” and “IMPORTANT WARNINGS” sections of this manual). Position your Allergy Pro 200 at least one foot ™...
oPerAting the Allergy Pro mAintenAnce ™ CONTROlS/SETTINGS: The Allergy Pro™ professional air purifier is almost maintenance free! Our true HEPA filter lasts up to twelve months, depending on use and environment conditions. It is recommended to replace the true HEPA filter every twelve months. Power Control – To operate the Allergy Pro 200 air purifier, turn dial clockwise to turn on the air ™ purifier. Turn dial counter-clockwise to OFF position to turn the unit off. Before replacing the true HEPA filter of your Allergy Pro ™ professional air purifier, turn off and unplug the unit from the electrical outlet and read all safety instructions and important warnings in this owner’s manual. Fan Speed Control – The Allergy Pro 200 has three different speeds of cleaning, HI, MED and ™ lOW. Turn the control dial clockwise to your desired speed. Replacing the True HEPA Filter 1. Make sure unit is turned off and unplugged. Release the inlet grill by pressing on the locking latch (see diagram of Main Parts). 2. Remove the inlet grill from the unit as shown below. 3 . Grasp the left and right frames of the True HEPA filter through the indentations on the sides of the filter enclosure and remove the filter. 4 . Insert a new True HEPA filter, then snap the inlet grill back into position. To Order A Replacement True HEPA Filter The true HEPA filter should be changed every six months, simply contact our customer service department at 1.800.875.8577.
cleAning & mAintenAnce troubleshooting Cleaning External Surfaces PROBlEM REASON SOlUTION 1. Turn off and unplug unit. 2. Use a washcloth slightly dampened with a little water and dishwashing soap to wipe the outer case surfaces. Unit will not operate. Control Dial not turned to Turn the Control Dial ON position. clockwise. 3. Do not allow water to slip into the internal parts as this could damage your unit and result in electrical shock and injury to you. 4. Allow the unit to thoroughly dry before use. Unit is unplugged. Check to ensure unit is plugged in. The inlet grill has not been Check to make sure filter installed & locked into place. is properly installed & locked into place. Reduced airflow or The inlet or outlet grill may Check to ensure nothing is poor filtering.