● When pull out the wide panel, the ZOOM will constantly be
7mm or 14mm. The <ZOOM> button will not work.

C.Fn: Setting Custom Functions

The following table lists the available and unavailable custom
functions of this flash.
C.Fn Custom Functions
Custom Function
Function
Signs
ST
Auto sleep
(standby)
BL
Backlighting
control
ID
Wireless ID
43
ZOOM displayed
format
1
.
Press the < ZOOM > Button for 2 seconds until C.Fn menu is
displayed.
2
Turn the Select Dial to select the Custom Functions.
.
3
Press the <SET> Button and the Setting No. blinks.
.
4. Turn the Select Dial to set the desired number. Pressing the
<SET> Button will confirm the settings.
5
Press the <ZOOM> Button to exit.
.
- 47 -
Using the Wide Panel
Pull out the wide panel and place it
over the flash head as shown. The
flash coverage will then be extended
to 7mm or 14 mm.
The catchlight panel will come out
at the same time. Push the
catchlight panel back in.
Low Battery Warning
If the battery power is low, <
> will
appear and blink on the LCD panel.
P l e a s e r e p l a c e t h e b a t t e r y
immediately. When the low battery
indicator is displayed, the ZOOM
can not be adjusted.
Setting No. Settings & Description
ON
ON
OF
OFF
10 sec.
Off in 10 sec.
OF
Always off
ON
Always lighting
OFF
Off
01-99
Choose any figure from 01-99
ON
43 format
OFF
135 format

Protection Function

1. Over-Temperature Protection
To avoid overheating and deteriorating the flash head, do not fire
more than 30 continuous flashes in fast succession at 1/1 full
power. After 30 continuous flashes, allow a rest time of at least 10
minutes.
If you fire more than 30 continuous flashes and then fire more
flashes in short intervals, the inner over-temperature protection
function may be activated and make the recycling time over 10
seconds. If this occurs, allow a rest time of about 10 minutes, and
the flash unit will then return to normal.
When the over-temperature protection is started,
the LCD display.
Number of flashes that will activate over-temperature protection:
Power Output Level
Number of Flashes
1/1
30
1/2 +0.7
40
1/2 +0.3
50
1/2
60
1/4(+0.3,+0.7)
100
1/8(+0.3,+0.7)
200
1/16(+0.3,+0.7)
300
1/32(+0.3,+0.7)
500
1/64(+0.3,+0.7)
1000
1/128(+0.3,+0.7)
Number of flashes that will activate over-temperature protection in
high-speed sync triggering mode:
Power Output
Times
1/1
15
1/2(+0.3,+0.7);
20
1/4(+0.3,+0.7)
30
1/8(+0.3,+0.7);
1/16(+0.3,+0.7)
40
2. Other Protections
The system provides real-time protection to secure the device and
your safety. The following lists prompts for your reference:
Prompts on LCD Panel
Meaning
E1
A failure occurs on the recycling system so that the
flash cannot fire.
Please restart the flash unit. If the problem still exists,
please send this product to a maintenance center.
E3
The voltage on two outlets of the flash tube is too high.
Please send this product to a maintenance center.
E9
There are some errors occurred during the upgrading
process. Please using the correct firmware upgrade
method.