Summary of Contents for PCB Piezotronics PCB Load & Torque 1102-03A
Page 1
Model 1102-03A Strain Gage Load Cell Installation and Operating Manual For assistance with the operation of this product,contact: PCB Load & Torque, Inc. Toll-free: 866-684-7107 24-hour SensorLine™: 716-684-0001 Fax: 248-888-8266 E-mail: LTInfo@pcbloadtorque.com Web: www.pcbLoadTorque.com...
Page 2
Piezotronics, user servicing or repair is critical test. not recommended and, if attempted, may void the factory warranty. Routine PCB Piezotronics maintains an ISO- maintenance, such as the cleaning of 9001 certified metrology laboratory and electrical connectors, housings, and offers calibration services, which are...
Page 3
E-mail: info@pcb.com representative. Warranty – All equipment and repair services provided by PCB Piezotronics, Inc. are covered by a limited warranty against defective material workmanship for a period of one year from date of original purchase. Contact...
CANISTER LOAD CELL OPERATION MANUAL 3.1 Dimensions 1.0 INTRODUCTION General purpose canister load cells manufactured by PCB Load & Torque are suitable for a wide range of general force measurement applications, including weighing, dynamometer use, and static material test machines. These load cells operate in tension and compression.
CANISTER LOAD CELL OPERATION MANUAL 5.3 Cable & Grounding Considerations 5.0 ELECTRICAL INSTALLATION Proper grounding and shielding is required to prevent Table 4 - Electrical Connections electrical noise in strain gage load cell measuring systems. Load Cell Receptacle: PT02E-10-6P The cable must be shielded twisted pairs with a drain wire. Mating Connector: PT02A-10-6S PCB Load &...
Page 9
CANISTER LOAD CELL OPERATION MANUAL 6.1.1 Measured Output 7.0 SHUNT CALIBRATION DESCRIPTION The applied load starting at zero is measured in five Shunt calibration is used to simulate a known tension or increments to full scale. Output (mV/V) is measured at each compression load on a load cell.
CANISTER LOAD CELL OPERATION MANUAL 8.0 MAINTENANCE 10. Keep a record of your observations, correct problems, or contact PCB factory for assistance. Routine maintenance of the canister style load cell should include cleaning the electrical connectors, housings, and mounting surfaces with solutions and techniques that will not 10.0 CALIBRATION / REPAIR SERVICES harm the physical material of construction.
Page 11
Model Number Revision: H STRAIN GAGE LOAD CELL 1102-03A ECN #: 43815 Performance ENGLISH OPTIONAL VERSIONS Measurement Range 200 lb 890 N Optional versions have identical specifications and accessories as listed for the standard Sensitivity(± 10 %) 2 mV/V 2 mV/V model except where noted below.
Page 12
PCB Load & Torque Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others without DESCRIPTION the written consent of PCB Load and Torque Inc. ADDED NOTE 1, WIRING CODE 38165 PT02E-10-6P RECEPTACLE WIRING CODE...
Need help?
Do you have a question about the PCB Load & Torque 1102-03A and is the answer not in the manual?
Questions and answers