8. Turn the T.E.N.S. off before applying or removing electrodes. There is nothing “magic” about Transcutaneous Electrical Nerve Stimulation 9. AGF-3X T.E.N.S. devices have no AP/APG protection. (TENS). TENS is intended to be used to relieve pain. The TENS unit sends Do not use it in the presence of explosive atmosphere and flammable mixture.
Chapter 4 : GENERAL DESCRIPTION The AGF-3X TENS is a battery operated pulse generator that sends electrical impulses electrodes to the body and reach the nerves causing pain. The device is provided with two controllable output channels, each independent of each other.
Chapter 8 : ACCESSORIES Pulse width(adjustable), frequency = 100 Hz 7. Wave Form Asymmetrical Bi-Phasic Square Pulse Each set AGF-3X TENS are completed with standard accessories and standard 8. Voltage 0 to 34 V (Load : 500 ohm) label as given below 9.
II.LABEL directly through the area of pain or localized enervation), a quick pulse rate The label attached to the back of device (setting greater than 80Hz on the Pulse Rate Control) is desired. The patient contains important message about this should not perceive individual pulses but rather have the sensation of steady device- model, serial number, supply continuous stimulation.
Chapter 11 : ATTACHMENT OF ELECTRODE LEAD WIRES Chapter 14 : ELECTRODE PLACEMENT The wires provided with the sys- The placement of electrodes can be one of the most important parameters in tem insert into the jack sockets achieving success with TENS therapy. Of utmost importance is the willing- located on top of the device.
2. Excess hair may be clipped with scissors; do not shave stimulation area. Saturation with water will reduce the adhesive properties. 3. Wipe the area with the skin preparation your clinician has recommended. Important Let this dry. Apply electrodes as directed. 1.
Page 9
higher frequencies, the lamp will appear to be constantly illuminated. 5. Mode Control 3. On/Off Switch and Intensity Control : Expose the controls by sliding front cover down from top of unit. This switch If both controls are in the off-position (white markings on the housing), the has 3 positions: B for Burst stimulation, N for Constant stimulation, and M for device is switched off.
(d)WARNINGS: 1. Do not attempt to charge any other types of batteries in your charger, other AGF-3X TENS can be used with a rechargeable battery when necessary. than the nickel-cadmium rechargeable batteries. Other types of batteries If you use rechargeable batteries, please follow the instructions.
- legibility of inscriptions and labels. - make sure the inscriptions and labels are not distorted. All AGF-3X TENS models carry a warranty of one year from the date of delivery. 3. Check Led The warranty applies to the stimulator only and covers both parts and labour - led must be illuminated when switched on.