External Timed Program

External Timed Program is completely controlled by PC, PC counts the time and changes voltage and current of power
supply.
Select External Timed Program tab to switch to the External Timed Program tab.
- Double click on the cell that you would like to set value. For example Step 2 voltage.
- Slide the bar to configure the value.
- Set time for this step to be running. The time range is between 0 to 9hours 59 minutes 59 seconds. You can click
up/down button to change value or directly input value. If the time value is set to 0, this step will be skipped.
- Select running cycle between 0-999. You can use slide bar to select or directly input value in text box. Input 0 means
run the program forever.
- Click on
button to start running cycle.
- In between program running cycle, click
- Click
to clear the setting.
button to stop program.