To turn on the machine
Making sure that the solu�on switch on the remote control is on the "OFF" posi�on. Press the start bu�on (one
resonator at a �me) and keep it pressed for 5 seconds a�er you hear combus�on star�ng (sounds like a small
explosion). It is necessary to keep the machine on for about 10 seconds to warm up before turning on the solu�on
switch. TIP: If the machine fails to start , press the button "KNOCKING" so pressure in the fuel tank can be re-
established. Press the start button again and repeat the above procedure until it starts .
To start fogging
Once the machine has heated up for 10 seconds, flick the solu�on switch to the ON posi�on. When you are ready to
start fogging, turn clockwise the Chemical Flow Regulator (FIG 1.12). Note: This valve also regulates the amount of
flow/chemical being used, by turning it le� to right.
To turn o the machine
Flick the solu�on switch to the OFF posi�on and press the STOP bu�on. Turn the Chemical Flow Regulator an�-
clockwise to stop the flow of chemical. Tip: A�er use, keep the machine in opera�on for 5 seconds to help get rid-off
any chemical mixture s�ll in the system.
MAINTENANCE
Cleaning the Chemical Tank and Pipes
Fill the chemical tank with 25% of clean water and turn on the unit. This will prevent corrosion and the accumula�on
of chemical deposits in the tank and pipes.
Spark Plug Maintenance
Remove the spark plug using a spanner or spark plug remover. Remove any carbon deposits between the electrode
and the earth sec�on with a wire brush. Make sure that there is a space of 3 to 5 mm between the electrode and the
earth.