TROUBLESHOOTING
At least one of
the +15V, -15V,
or +5 LEDs on
the QNET HVAC
board are not lit.
The +15 V; -15 V;
and +5 V LEDs
on the QNET
HVAC board, are
bright green but
the External
Power LED is not lit.
STILL NEED HELP?
Register your QNET board at https://www.qnetregistration.com to recieve regular product updates.
QNET 2.0 Rotary Pendulum
LEARN MORE
©2015 Quanser Inc. All rights reserved. NI ELVIS is a trademark of National Instruments. QNETs were developed by Quanser exclusively for National Instruments.
Review the following recommendations before contacting Quanser's technical support engineers
Ensure that the PCI connector on the QNET board is properly connected to the female
connector on the NI ELVIS II unit.
Check that the system power switch, located on the back panel of the NI ELVIS II unit,
and the prototyping power switch, situated on the top of the NI ELVIS are ON.
If one or more of the +15V; -15V; or +5V LEDs is still not lit, then the 15V or +5V fuse(s)
on the Protection Board of the NI ELVIS II has been triggered. Similarly, if the External
Power LED is still not lit after connecting the QNET HVAC power, the Variable
Power Supplies Fuses on the NI ELVIS II Protection Board have been triggered. See the
Protection Board Fuses in the NI ELVIS II User Manual.
Ensure the supplied QNET power supply is connected to the QNET board.
If the External Power LED still does not light up, the QNET fuse may need to be replaced.
Refer to the QNET HVAC User Manual for details.
For further assistance from a Quanser engineer, contact us at tech@quanser.com
or call +1-905-940-3575.