Robe Anolis E-Box Remote User Manual
Hide thumbs Also See for Anolis E-Box Remote:

Advertisement

Quick Links

Version 1.4
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Anolis E-Box Remote and is the answer not in the manual?

Questions and answers

Summary of Contents for Robe Anolis E-Box Remote

  • Page 1 Version 1.4...
  • Page 2: Table Of Contents

    E-box Remote Table of contents 1. Safety information ....................... 3 2. Fixture description ......................4 3. Mounting ..........................6 4. Eminere Remote modes ..................... 9 5. E-box Remote menu ......................13 5.1 DMX Addr ........................13 5.2 Info ..........................13 5.3 Personality .........................
  • Page 3: Safety Information

    1. Safety information FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR E-box Remote! Save it for future reference. DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT! Make sure that the available voltage is not higher than stated on the fixture. Always disconnect the fixture from AC power before removing its cover.
  • Page 4: Fixture Description

    2. Fixture description A - Top cover B - Top cover screws C - Mounting holes D - Antenna cover E - Display F - Control buttons G - Screws of terminal blocks cover H - Terminal blocks cover View without top cover 1 - LED Output 1 (cable gland M20x1.5) 2 - LED Output 2 (cable gland M20x1.5) 3 - Power IN (cable gland M20x1.5)
  • Page 5 Connection points...
  • Page 6: Mounting

    3. Mounting Fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. Setting and addressing the E-box Remote without top cover can be done by a qualified person only! Note for cable glands.
  • Page 7 DMX connection Data + Data - Data ground (shielding) Ethernet connection Function Eminere Remote connection Mark Function Wire LEDs + DATA + Orange DATA - Black LEDS - White Ground Not connected Example of connection...
  • Page 8 NOTE: Each line of Emineres Remote connected to the LED output of the E-box Remote has to be terminated at the last fixture. EITHER connect a 120 Ohm resistor between terminals D+ and D- in the last fixture, OR terminate via RDM as described on page 11.
  • Page 9: Eminere Remote Modes

    Pass-Thr - (Pass through). LED modules are switched to an internal parallel connection. DMX addressing of connected LED modules has to be done manually by means of the Robe Universal Interface (or its wireless version Robe Universal Interface WTX) and the software RDM Manager.
  • Page 10 Examples of RDM manager screenshots for one connected LED module. Initial screen of the RDM manager: Click on the device to show options of the Control panel Options in the Control panel allow you to set DMX address and Personality for each LED module. Click on the green arrow to save adjusted values...
  • Page 11 Options in the control panel: Possible numbers of connected LED modules for each E-box mode are stated in chapter 3. "Mounting". If no DMX is received, the unit will turn on the predefined Demo mode. You can modify it by setting the unit to a desired look via DMX and then save this via RDM by setting the "Init position LEDs"...
  • Page 12 The function "Pixel swap" from RDM control panel allows you to swap the pixel order. Example:...
  • Page 13: E-Box Remote Menu

    5. E-box Remote menu The E-box Remote is equipped with 2-row LCD display and four buttons which allows to address the fixture and set the fixture´s behaviour according to your needs. The four control buttons have the following functions: - ESCAPE button - to escape function or menu. - ENTER button - to select a function or confirm adjusted value.
  • Page 14: Personality

    WL - version of wireless DMX module (if installed). IP Addr - this menu item shows the current IP address (the IP address "runs" on display). RDM UID - select this menu item to read the RDM UID (the RDM UID "runs" on display). on display).
  • Page 15: Test Programs

    button on the control panel. Display Lightness - select this menu item to adjust the display intensity (0-100%). Display Contrast- select this menu item to adjust contrast of the display (0-100%). RGB(W) Split - this menu item allows you to select a way how the last pixel of the actual DMX Universe will be split to the next DMX Universe if the actual DMX Universe does not offer enough free channels for the pixel.
  • Page 16: Software Update

    6. Software update E-box Remote software update is done via an Ethernet connection between a computer running a ROBE Up- loader software and E-box Remote or using the Robe Universal Interface (Robe Universal Interface WTX and the ROBE RDM Uploader software.
  • Page 17 2. By means of the Robe Universal Interface (Robe Universal Interface)
  • Page 18: Dmx Protocol

    7. DMX protocol Version 1.0 Channel Function Type of control Value Red LEDs (Pixel 1) 0-255 Red LEDs saturation control (0-100%) proportional Green LEDs (Pixel 1) 0-255 Green LEDs saturation control (0-100%) proportional Blue LEDs (Pixel 1) 0-255 Blue LEDs saturation control (0-100%) proportional White LEDs (Pixel 1) 0-255...
  • Page 19: Technical Specifications

    8. Technical specifications Input voltage 120-240 V AC; 277V AC Frequency 50/60Hz Power consumption 520W Fuse 1 T6.3A/500V AC Fuse 2 T8A/250V AC Fuse 3 T8A/250V AC LED Output Number of outputs Voltage 48V DC Max output power 380W per output Total Output power 480W max.
  • Page 20: Disposing Of The Product

    Menu DMX preset added, menu Devices removed, Eminere connection changed April 7, 2022 Specifications are subject to change without notice. Copyright © 2021-2022 Robe Lighting - All rights reserved Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici...

Table of Contents