Citizen CBM-262 User Manual page 50

Line thermal printer
Hide thumbs Also See for CBM-262:
Table of Contents

Advertisement

Chapter 6 Interfaces
Pin No.
31
32
33
34
35
36
IN indicates signals from the Host to the printer, and OUT indicates signals from the
printer to the Host.
* means negative logic signals.
6
40
Signal Name
Direction
When this signal goes "Low," the printer becomes
BUSY. It is initialized after all the data are printed.
BUSY is not cleared until this signal goes "High."
*INIT
IN
A pulse width of 1
receiving end.
(See "When Receiving the INIT Signal.")
This signal indicates that the printer is in the error state.
It goes "Low" under any one of the following condi-
*FAULT
OUT
tions.
• Paper End
• When an abnormal operation is detected.
GND
Signal line ground.
DRAWER
KICK
OUT The drawer kick connector's status signal is output.
STATUS
FUSE
OUT Connected to +5 V through a 3.3k ohm resistor.
Not used.
Function
sec or longer is required at the