Power INTAKE
Safety Warnings:
• The maximum test pressure a Power INTAKE
• Slippage of a Power INTAKE
Intake / Exhaust system, coefficient of friction, internal pressure of the Power INTAKE
the accuracy of inflation instruments.
• Generally, a Power INTAKE
slipping when test pressure exceeds 50% of the internal inflation pressure. Inflation pressure and back
pressure limitations are subject to temperature / humidity change.
• Power INTAKE
Adapters should NEVER be inflated over 1.6 times its outside diameter.
• Debris, protrusions and residue in the Intake / Exhaust system could weaken and / or rupture the
bladder of the Power INTAKE
warranty. Redline Detection shall not be responsible for any incidental or consequential damages.
• Power INTAKE
Adapters must be mechanically anchored with the provided chain / cable to a secure
location before use.
• Power INTAKE
Adapters slippage under test pressures may cause property damage or injury.
• NEVER use inflation pressure with Power INTAKE
capacity of the weakest component in the system under test.
• NEVER use Power INTAKE
• Before use: Refer to Power INTAKE
limitations and tether restraint installation instructions.
Installing Power INTAKE
1. Install Power INTAKE
are no obstructions or sharp edges that might puncture bladder when inflated. Power INTAKE
Adapters must insert completely inside ducting / tubing.
2. Install safety chain / cable to a secure location.
3. Inflate Power INTAKE
release. If release occurs, reinflate to 30 PSI (2 BAR).
4. Firmly tug on safety chain to insure Power INTAKE
5. Attach vapor hose for testing.
Proper Installation
Removal of Power INTAKE
1. Remove vapor hose (or block off adapters) at quick coupler to deflate tested system
2. ONLY AFTER system under test is fully depressurized, release internal pressure of Power INTAKE
slowly by depressing Schrader valve
3. Detach safety chain / cable
4. Remove Power INTAKE
6

ADAPTERS INSTALLATION

Adapters is influenced by many factors including debris / residue in the
Adapters properly inserted into an Intake / Exhaust system may begin
Adapters. Bladder failures due to misuse or abuse are not covered by
Adapters when its failure could cause injury or catastrophic damage.
Adapters Installation and Inflation procedures, back pressure
Adapters:
Adapters fully into intake system ductwork or exhaust tubing. Make sure there
Adapters to 30 PSI (2 BAR) maximum. If over inflated, pop off safety valve may
Adapters:
Adapters from ductwork, making sure not to rub across sharp edges
Adapters may restrain can only be estimated.
Adapters or a test pressure that is greater than the
Adapters is firmly installed and properly secure.
Improper Installation
Adapters, and