3. Dedust the filter (see chapter Dedusting
the filter).
4. Check the seating of the filter and cor-
rect if necessary.
5. Replace the filter (see chapter Replac-
ing the filter).
Escaping dust when vacuuming
1. Check the seating of the filter and cor-
rect if necessary.
2. Dedust the filter (see chapter Dedusting
the filter).
3. Replace the filter (see chapter Replac-
ing the filter).

Disposal

At the end of its service life, the device is to
be disposed of in accordance with statutory
regulations.

Warranty

The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)

Technical data

Electrical connection
Mains voltage
Phase
Power frequency
Nominal power
Maximum power
Protection class
Protection class
Maximum permissible
mains grid impedance
V
220-
240
~
1
Hz
50-60
W
2100
W
2300
IPX4
I*
Ω
0.224+
j0.140
English
Dimensions and weights
Typical operating weight
Length x width x height
Effective filter area
Ambient conditions
Storage temperature
Device performance data
Container capacity
Vacuum (max.)
Max. volume flow with
suction hose DN50, L=3 m
Max. volume flow with
suction hose DN40, L=3 m
Max. volume flow with
suction hose DN50, L=5 m
Max. volume flow with
suction hose DN40, L=5 m
Suction hose connection
Nominal width of the suc-
tion hose
Waste hose order number
Determined values in acc. with EN
60335-2-69
Hand-arm vibration value m/s
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Mains cable
Type
Part number
Cable length
* with elements of protection class II ar-
rangement
Subject to technical changes without no-
tice.
kg
47
mm
680 x
655 x
1435
2
m
1.5
°C
-10-40
l
25
kPa
19.0
3
m
/h
250
3
m
/h
205
3
m
/h
230
3
m
/h
190
NW
DN70
DN40/
50
6.907-
506.0
2
< 2.5
2
m/s
1
dB(A) 77
pA
dB(A) 2
H07R
N-F
3G1.5
2
mm
6.650-
035.0
m
10
19

Advertisement

loading