5. Input Output Signal Specifications
HD/VD Output Amplitude Specifications
HD
VD
The amplitude level is the representative value
when terminated with 10k . Output is enabled
when the rear panel HD/VD signal input/output
switch is set to the INT side.
VIDEO INDEX Output Specifications
525H (Partial scanning OFF)
175H (Partial scanning ON)
The amplitude level is the representative value
when terminated with 10k .
VD Input Specifications
5H to 21H
* Input impedance: 75 or 1k or greater
* Input amplitude 2.0 to 5.0 Vp-p (75 termina-
tion ON or OFF)
* Voltage and pulse width were measured at
pin 7 of the 12-pin connector located on the
rear panel.
HD Input Specifications
4.5V
0V
4.5V
* Input impedance: 75 or 10k or greater
* Input amplitude 2.0 to 5.0 Vp-p (75 termina-
0V
tion ON or OFF)
* Voltage and pulse width were measured at pin
6 of the 12-pin connector located on the rear
panel.
Trigger Pulse Specifications
4.5V
0V
* Input impedance: 10k or greater
* Voltage and pulse width were measured at
pin 11 of the 12-pin connector located on the
2.0 to 5.0Vp-p
rear panel.
PART Input Specifications
H: 2.0 to 5.0 V
L: 0 to 0.4 V
2.0 s to 5.0 s
(Positive polarity mode)
More than 2 s
(Negative polarity mode)
More than 2 s
2.0 to 5.0Vp-p
2 to 5.0V
0 to 0.4V
2 to 5.0V
0 to 0.4V
15