Installation process for vertical water supply/ concrete pool with brush-applied sealant..............13 Installation process for vertical water supply/ subsequent installation......14 Spare parts Mushroom ..............15 Concrete tile pool / 90° water supply ................15 Concrete tile pool / vertical water supply ..............16 Concrete liner pool / vertical water supply ..............
Proper use The mushroom was developed for use in public swimming pools. It can be used in both indoor and outdoor pools. The entire system or parts of it are not suitable for use in other systems.
Operating pressure Max. perm. pressure 0.8 bar Curtain diameter Ø 1500 mm Ø 1800 mm Ø 2300 mm Flow rate 90 m 120 m 150 m Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...
The suction-end shut-off unit (P3) must always be completely open while the system is in operation. Water is directed through the pipe system (P4) to the mushroom (P5). An additional shut-off unit (P6) is built into the pipe system (P4) for individual control of the flow rate.
OPERATOR’S MANUAL General description The fluvo mushroom consists of an installation kit, an assembly kit and a fluvo standard pump. fluvo mushrooms are available in 3 different curtain sizes (a= ø 1500 mm, ø1800 mm, ø 2300 mm) and for 4 different types of pools. The stand pipe height up to the bottom edge of the umbrella isc= 2200 mm for all sizes.
Counter-sunk screw Screen d= DN 125 Fig. 3 Important: Before placing the screen (10) on the stand pipe (07), seal both pipes with DIRKO sealant. Fig. 4 Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...
Before loosening the form wall (W), the fastening parts that are no longer needed (02, 03, 04) and the protective cap (H) must be removed. Protective cap Form wall Locking screws Distance washer Installation kit d= DN 125 Fig. 5 Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...
Screen Screen d= DN 125 Fig. 6 Important: Before placing the screen (10) on the stand pipe (07), seal both pipes with DIRKO sealant. Fig. 7 Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...
(H) must be removed. Then remove the fitting (C) from the installation kit (13). Fitting Protective cap Form wall Installation kit d= DN 125 Fig. 8 Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...
After loosening the form wall (W), the protective cap (H), which is no longer needed, must be removed. Counter-sunk screw Protective cap Flange Form wall Flange Installation kit d= DN 125 Fig. 11 Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...
= ø 180 mm Fig. 15 g= ø 360 mm Important: Before placing the screen (10) on the stand pipe (07), seal both pipes with DIRKO sealant. Mushroom Schmalenberger GmbH + Co. KG Version: 27109 - B D-72072 Tübingen / Germany...