THOMSON STUDIO CAMERA LDK 20(S) Technical Manual page 65

Studio camera
Table of Contents

Advertisement

Encoder Board PAL
B-Y amplitude
11. On the encoder board disconnect MP7 from ground and connect MP8 to ground.
12. Adjust with the B-Y gain potentiometer until the colour vector dots correspond with the indication marks on
the U-axis of the graticule.
Measure at:
Adjust with:
CVBS out
ZR202
13. Disconnect MP8 from ground.
R-Y / B-Y phase
14. Switch vectorscope from Standard to PAL mode.
15. If the vector dots are not superimposed on each other adjust the phase with L8.
Measure at:
Adjust with:
CVBS out
L8
16. Switch vectorscope from PAL to Standard mode and check that the vector dots are exactly in the vectorscope
boxes.
Measure at:
Adjust with:
BURST ADJUSTMENTS
Burst phase
17. Measure in second quadrant of vectorscope.
Adjust the input sensitivity potentiometer of the vectorscope so the burst vectors just touch the circle graticule.
18. Adjust the burst phase potentiometer for 90° phase output.
Measure at:
Adjust with:
CVBS out
ZR211
Adjustments
Required result:
Correct:
%
120
100
80
60
40
20
20
43
Required result:
Correct:
%
120
100
80
60
40
20
20
43
Required result:
Correct:
%
120
100
80
60
40
20
20
43
Technical Manual LDK 20(S) - Studio Camera
VOLT
cy
R
0.7
g
MG
V
75
100
5
b
YL
U
0
yl
B
-5
0
mg
G
r
CY
0.3
Incorrect:
VOLT
%
120
cy
R
0.7
100
g
MG
80
V
75
60
100
5
b
YL
40
U
0
yl
B
20
-5
0
mg
20
G
r
CY
0.3
43
VOLT
cy
R
0.7
g
MG
V
75
100
5
b
YL
U
0
yl
B
-5
0
mg
G
r
CY
0.3
VOLT
R
cy
0.7
g
MG
V
75
100
5
b
YL
U
0
yl
B
-5
0
mg
G
r
CY
0.3
4-39

Advertisement

Table of Contents
loading

Table of Contents