EMI AmericaSeries LLC-09 Quick Start Manual

Doctless split system

Advertisement

CLICK ANYWHERE on THIS PAGE to RETURN to HVAC MANUALS & REPAIR GUIDES at InspectApedia.com
GENERAL INFORMATION
Installation, Operation, & Maintenance Guide
Specifications & Performance Guide
Policy Bulletins
SYSTEM DESIGN
* Single Zone indicates that each unit has one compressor to be
connected to a single air handler.
** Multi-zone describes a unit with more than one compressor
for more than one air handler.
The Ductless Split System of Choice
limited range
DUCTLESS SPLIT SYSTEM
Service and Technical Guide
P/N 240-2985, Rev. 1.2 [07/01]
SITE INFORMATION/REQUIREMENTS
1
Made in Rome, New York, USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AmericaSeries LLC-09 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EMI AmericaSeries LLC-09

  • Page 1 CLICK ANYWHERE on THIS PAGE to RETURN to HVAC MANUALS & REPAIR GUIDES at InspectApedia.com DUCTLESS SPLIT SYSTEM Service and Technical Guide P/N 240-2985, Rev. 1.2 [07/01] GENERAL INFORMATION Installation, Operation, & Maintenance Guide Specifications & Performance Guide Policy Bulletins SYSTEM DESIGN * Single Zone indicates that each unit has one compressor to be connected to a single air handler.
  • Page 2 PERATION USING TEST PINS NOTE: If the SHC condenser is equipped with low ambient fan control for cooling, The fan will remain off (while in cooling mode) until EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 3: General Wiring Procedures

    NOTE: If EMI equipment is installed in a mixed equipment system without prior approval, EMI will void ALL warranties. NOTE: If the condenser coil is heavily frosted GENERAL WIRING PROCEDURES with ice, it is likely that the “Defrost Sensor” is already closed so the “R and DFT”...
  • Page 4 Check drier specifications for charge recommendations. ANTI-SHORT CYCLE TIMER (ASCT) TRAP NSTALLATION ROCEDURE LOW AMBIENT OPTIONS NOTE: Avoid excessive oil buildup. The P-trap EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 5: System Troubleshooting

    SYSTEM TROUBLESHOOTING NOTE: Multiple compressor units use one (1) fan for all of the compressors. MBIENT ROUBLESHOOTING WARNING!! It is illegal to discharge refrigerant into the atmosphere. Use proper reclaiming methods & tools when installing or servicing equipment. CONDENSATE PUMPS & DRAIN NOTE: Condensing units built before January NOTE: Before completing installation, test 1, 1994, require the service panel be placed...
  • Page 6: Compressor Replacement

    ECOMMENDED ROCEDURE FOR OMPRESSOR EPLACEMENT REMEMBER: Remove the suction line drier after a few days of continuous operation. EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 7: Dip Switch Settings

    Operation & Maintenance Guide WSP/WHP & FSP/FHP UNIT MOUNTED ELECTRONIC CONTROLS (FEATURES) NOTE: EMI technical service can help you di- agnose problems with your unit(s). Feel free to call us Monday through Friday from 8am- 5pm at (315) 336-3716.
  • Page 8: Control Options

    CO OL MO DE Button FAN MODE Button NOTE: Operational range is 55-90° F in 1.0° increments. B AT T E R IE S INCL U DE D EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 9 NOTE: Most condenser manufacturers do not supply low volt transformers with their condensers. When connecting an EMI evaporator to a non-EMI condenser, a transformer may have to be added to the system to provide 24v power. OOLING NLY WITH LECTRIC...
  • Page 10: Freeze Protection

    (Y) signal to the condenser. This will prevent the evaporator Auto from generating more condensation and Auto High spilling out of the unit. EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 11 Auto * Some EMI heat pump condensers are equipped with a low tem- perature cutout that will shut down the compressor & energize the Heat Cool indoor electric heat when outdoor temperatures fall below 0° F. Heat Cool High OOLING...
  • Page 12: System Data

    NOTE: EMI does not stock or recommend electric heat add-on kits for field installation. It is critical that, if you can foresee the need for electric heat in your EMI evaporator, you initially order it as a factory installed option. REMOTE THERMOSTAT PLACEMENT SYSTEM DATA NOTE: A signal must be present at the “G”...
  • Page 13: System Data Sheet

    SYSTEM DATA SHEET The Ductless Split System of Choice Made in Rome, New York, USA...
  • Page 14 Total Adjustment= (Line Charge/FT) x Line Length System Total= Factory Charge +Total Adjustment NOTE: Round down to nearest ounce and allow for gauges and hoses. EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 15 EFRIGERANT HARGE ABLES INGLE TRAIGHT l a t l a t o t c t s y l a t l e d l a t ) t f ( ) t f ( l a t l a t o t c t s y l a t...
  • Page 16 NOTE: Round down to nearest ounce and allow for gauges and hoses. EX- MC4-24/CSP-24 with 18’ line length (.56) 18= 10oz. (Total Adjustment) 60oz.+10oz.= 70oz. (System Total) EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 17 EFRIGERANT HARGE ABLES ULTI EFRIGERANT HARGE ABLES ULTI TRAIGHT l a t l a t o t c t s y l e d l a t l a t ) t f ) t f ( - e t l a t l a t l a t...
  • Page 18 *Suction temperature taken 6” from Compressor Suction Port PERATION HARTS ULTI (O.D. = Outdoor) Cooling-Based on 80/67º F Indoor Temp. ) MH PERATION HARTS ULTI Heating-Based on 70º F Indoor Temp. EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 19 ) SCC/SHC *Suction temperature taken 6” from Compressor Suction Port PERATION HARTS INGLE (O.D. = Outdoor) Cooling-Based on 80/67º F Indoor Temp. ) SHC PERATION HARTS INGLE Heating-Based on 70º F Indoor Temp. The Ductless Split System of Choice Made in Rome, New York, USA...
  • Page 20 EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 21 0 - Std. A - Z 9,000 / 12,000 BT U - 12 0 - Standard X - Special 0 - EMI (Std) E - Comfort Aire 115V 60Hz - A 208V 60Hz - B 02/97 (Mechanical) - A 230V 60Hz - C...
  • Page 22 T ecumseh Rotary - A Carrier Rotary - D Special - X 0 - Low Volt Interconnect, Extended Run (Std) E - Hawaii Package X - Special EMI Products are subject to ongoing development. Products & Specifications may change without notice.
  • Page 23 SERIAL NUMBER DECODING 1-99-C-9305-10 Each EMI product is assigned a serial number that contains information about that specific piece. This Week of Year Year serial number is found on the bottom left of the rating Manufactured plate (above the bar code) and breaks down as follows:...
  • Page 24 The remedies provided for in this warranty are exclusive and shall constitute the only liabilities on the part of EMI including any statements made by any individual which shall be of no effect.